12 VOLT OUTPUT:
A regulated 13.8 VDC output is available to power detectors and other equipment. This output
is available from two sets of terminals 12V and 0V. The output is protected by an
Automatic Reset fuse.
A maximum load of 500mA may be connected to these terminals.
SIREN:
The on-board siren driver will drive a maximum of 3 x 8 ohm horn speakers (Ness Part No.
NOI110 or 100-171 Internal Siren). The output will reset at the end of siren time (P29E) or
whenever the panel is reset, whichever comes first. This output has an internal Resettable fuse.
STR - Strobe:
A latched 12VDC output for connecting strobe lights. As of D16 Version 4.5, this output will
reset after 72 hours (3 days) or when the panel is disarmed.
(D16 versions prior to V4.5 allow indefinite strobe operation, until the panel is reset).
A maximum of 2 x 1 Watt Strobes (Ness Part No. NOI300) can be connected to this output.
The output is protected by an Automatic Reset fuse.
RESET:
A 12V DC output for connecting Ness Sirens, piezo sirens or relays, etc. This output will reset
at the end of siren time (P29E) or whenever the panel is reset, whichever comes first.
A maximum of 3 x 12V piezo Sirens (Ness Part No. NOI240, NOI 230, 100-238) or 2 X Ness
Piezo (Part No 100-172) can be connected to this output. The output is protected by an
Automatic Reset fuse.
J3 HEADER
Aux1:
This output is an open collector (switch negative) which can supply a maximum of
100mA. Zone alarms may be selected to trigger this output by option P58E.
The J3 header is also used to connect to the optional D16 Output Expander.
Aux2:
This output is an open collector (switch negative) which can supply a maximum of
100mA. Zone alarms may be selected to trigger this output by option P59E.
Arm1:
This output is an open collector (switch negative) which can supply a maximum of
100mA. This output is turned on when Area 1 is armed.
Arm2:
This output is an open collector (switch negative) which can supply a maximum of
100mA. This output is turned on when Area 2 is armed.
12V:
12V DC ouput for accessories. Maximum current draw 100mA.
0V:
12V ground.
OUTPUTS
OUTPUT FUSING
The 12V ouputs, Siren, Reset and Strobe outputs are protected by Automatic Reset electronic
fuses. These outputs will automatically reset once the overload is removed.
J3
OPEN COLLECTOR
OUTPUTS
AUX OUTPUTS
The D8 and D16 Aux1 and Aux2
outputs can now be driven by a
number of different conditions and
alarms.
The following is a summary of the
Aux1 and Aux2 program options and
conditions.
AUX1 CAN BE TRIGGERED BY:
• Any zone alarm if programmed by
option P58E. The output remains on
until the panel is reset/disarmed.
• A Radio Supervision alarm if option
P66E 5E is on. The output remains on
until the panel is reset/disarmed.
• Remotely by telephone.
• A Ness RK3 or RK4 Radio Key
PANIC button if options P68E 3E or
4E are on.
(if 3E is on, the output Toggles, if 4E is
on, the output Pulses. If both 3E & 4E
are on, the output will Pulse).
• A Ness RK4 Radio Key AUX button
if options P68E 3E or 4E and 7E are
on.
AUX2 CAN BE TRIGGERED BY:
• Any zone alarm if programmed by
option P59E. The output remains on
until the panel is reset/disarmed.
• A Radio Supervision alarm if option
P66E 6E is on. The output remains on
until the panel is reset/disarmed.
• Remotely by telephone.
• A Ness RK4 Radio Key AUX button
if option P69E 7E or 8E are on.
(if 7E is on, the output Toggles, if 8E is
on, the output Pulses. If both 7E & 8E
are on, the output will not work).
NOTE:
Aux1 and Aux2 will both be
turned off by a Pulse on
any
other
output, (including siren/strobe).
For example, if either Aux output is
toggled on, the output will be turned
off by the Radio Key arm/disarm
strobe flash.
This makes it necessary to disable all
‘pulsing’ outputs if toggled Aux
outputs are to work correctly.
BACKUP BATTERY
A properly charged battery MUST be installed to ensure the Siren, Strobe and Reset outputs
operate correctly.
SIREN LOAD
A maximum output of 2.0A continuous is available from the SIREN, and RESET outputs and
200mA from the STR output.
Recommended maximum power load:
3 x Horn speakers (SIREN output)
2 x Strobe lights (STR output)
2 x Ness Internal Sirens (100-172) (RESET output)
Note:
(This assumes no more than 500mA is being drawn from the 12V device output).