P R O G R A M M I N G
NESS D16 (V4.6) CONTROL PANEL - INSTALLER MANUAL
QUICK START PROGRAMMING
Use one of these programming summaries for fast setup of your D16 as a
Local, Audible Monitored or Central Station Monitored system.
The control panel will be ready for use immediately.
QUICK START 1
LOCAL SYSTEM
Quick Start 1 shows you how to
change User Code 1 (the
Master Code).
By default, the dialler is
disabled until programmed.
1
Enter User Program Mode
Program Light is ON
2
Selects the option for User Code 1
3
Enter the new User Code
Can be 3 to 6 digits long
4
Enter the new User Code again
5
To exit Program Mode
STEP
QUICK START 1 - step by step
DESCRIPTION
COMMENT
Program light turns OFF
KEY STROKES
2 3
1
1 1
The
code is displayed by the
keypad lights, followed by 3 beeps
new
The
code is displayed by the
keypad lights, followed by 3 beeps
existing
QUICK START 2
AUDIBLE MONITORING
Quick Start 2 shows you how to
change User Code 1 (the
Master Code), enable Audible
Monitoring and program 1
telephone number. This will
enable the dialler to report
alarms to any telephone
including mobile phones.
QUICK START 2 - step by step
Enter User Program Mode
Enter Installer Program Mode
Program Light is ON
Program Light is FLASHING
Selects the option for User Code 1
Enter the new User Code
Can be 3 to 6 digits long
Enter the new User Code again
At P86E, turns ON option 4
Selects the option for Telephone No.1
Enter the telephone number
Audible Monitoring enabled
Can be up to 15 digits long
To exit Program Mode
Program light turns OFF
KEY STROKES
DESCRIPTION
COMMENT
1
2
3
4
5
6
7
8
9
STEP
1 1
8 6
4
7 0
Up to 15 digits
2 3
1
0 0 0 0 0 0
The
code is displayed by the
keypad lights, followed by 3 beeps
new
The
code is displayed by the
keypad lights, followed by 3 beeps
existing
See page 46 for further information on the operation of Audible Monitoring.
7 2
QUICK START 3 - step by step
Enter User Program Mode
Enter Installer Program Mode
Program Light is ON
Program Light is FLASHING
Selects the option for User Code 1
Enter the new User Code
Can be 3 to 6 digits long
Enter the new User Code again
At P86E, turns ON option 2
Selects the option for Telephone No.1
Enter the Telephone Number
Enter the Account Number
Central station Monitoring enabled
Existing Ph No (if any) displayed
Can be up to 15 digits long
Must be 4 digits
To exit Program Mode
Program light turns OFF
DESCRIPTION
COMMENT
1
2
3
4
5
6
7
8
9
10
STEP
1
2
3
KEY STROKES
1 1
8 6
2
7 0
Up to 15 digits
2 3
1
0 0 0 0 0 0
The
code is displayed by the
keypad lights, followed by 3 beeps
new
The
code is displayed by the
keypad lights, followed by 3 beeps
existing
Option P86E 2E is ON by factory default. This option only needs to be turned ON if previously
programmed OFF.
Account Number to identify the premises - supplied by the Central Station
The
tation’s receiver telephone number - supplied by the Central Station
Central S
QUICK START 3
CENTRAL STATION
MONITORING
Quick Start 3 shows you how to
change User Code 1 (the
Master Code), enable Central
Station Monitoring and
program 1 telephone number.
This will enable the dialler to
report alarms to a Central
Station.
*
Factory default Master Code is: 123
*