57
57
57
57
57
N E S S R A D I O
NESS D16 (V4.6) CONTROL PANEL - INSTALLER MANUAL
RADIO DEVICE PROGRAMMING
Each of the 16 zones of the D16 can be a radio zone. Once programmed, zones
can accept both Radio Devices and normal zone inputs simultaneously.
The optional 100-200 Ness Radio Interface is required for Radio Devices to
operate. A Radio Device is any type of Ness transmitter.
PROGRAMMING RADIO DEVICES
Up to 16 Radio Devices can be assigned, (one per zone).
PROGRAMMING SEQUENCE - NO RESTORALS
Suitable for 100-663
Radio PIR
, 100-665
Radio Pendant
, 100-203
Radio
Smoke Detector
.
➊
Select a zone using P101E - P116E
P101E - P116E
P101E - P116E
P101E - P116E
P101E - P116E
The ARMED light will be ON if a Radio Device is already programmed to the zone. Press 0E to delete.
➋
Press 1E
1E
1E
1E
1E
The READY light will turn ON to indicate that the zone is ready to accept the Radio Device.
➌
Trigger the Radio Device
A. If the Radio Device is accepted, the READY light will turn off, the ARMED light will turn on and 3 beeps
will sound.
B. If the READY light stays on and a warning beep sounds, the Radio Device is already assigned to
another zone and must be cleared from that zone first.
C. If SUPERVISED SIGNALS have also been successfully recognised, the TAMPER light will turn ON.
EXAMPLE:
To program a Radio PIR on zone 16:
P116E 1E
Trigger the Radio PIR (or simply connect the battery)
PROGRAMMING SEQUENCE - WITH RESTORALS
Suitable for 100-662
Radio Reed Switch.
➊
Alarm the reed switch, ie., move the magnet away from the switch
Leave the reed switch in the alarm condition and wait until radio transmission has stopped.
➋
Select a zone using P101E - P116E
P101E - P116E
P101E - P116E
P101E - P116E
P101E - P116E
The ARMED light will be ON if a Radio Device is already programmed to the zone. Press 0E to delete.
➌
Press 1E
1E
1E
1E
1E
The READY light will turn ON to indicate that the zone is ready to accept the Radio Device.
➍
Restore the reed switch (place the magnet next to the switch)
A. If the Radio Device is accepted, the READY light will turn off, the ARMED light will turn on and 3 beeps
will sound.
B. The MEMORY light will turn on to indicate that this device sends Restorals.
C. If the READY light stays on and a warning beep sounds, the Radio Device is already assigned to
another zone and must be cleared from that zone first.
D. If SUPERVISED SIGNALS have also been successfully recognised, the TAMPER light will turn ON.
EXAMPLE:
To program a Radio Reed Switch with Restorals on zone 15:
Alarm the reed switch
P115E 1E
Restore the reed switch
P101E - P116E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
No Radio Devices
NOTES:
• Radio Device programming is done by
‘learning’ the code by radio.
• Radio Devices codes can only be deleted
by keypad.
• Some Ness Radio Devices send separate
Alarm and Restore signals.
• Ness Radio Keys (100-664), can be
programmed to operate on radio zones,
but they are normally used to operate
Radio Codes as described on page 56.
• Late model Ness Radio PIRs (100-663)
and Radio Reed Switches (100-662)
send Supervision signals.
SUPERVISION RELATED OPTIONS:
P65E
Supervised Radio Zones
P66E 1E-8E
Radio Supervision Alerts
P67E
Radio Supervision Time
P75E 12E
Radio Supervision Fail Report
• RELATED OPTIONS:
P09E-P10E
Programming Radio Keys
ZONE
OPTION No
Zone 1
P101E
Zone 2
P102E
Zone 3
P103E
Zone 4
P104E
Zone 5
P105E
Zone 6
P106E
Zone 7
P107E
Zone 8
P108E
Zone 9
P109E
Zone 10
P110E
Zone 11
P111E
Zone 12
P112E
Zone 13
P113E
Zone 14
P114E
Zone 15
P115E
Zone 16
P116E
RADIO DEVICES - OPTION TABLE
DELETING A RADIO DEVICE:
➊
Use P101E
P101E
P101E
P101E
P101E to P116E
P116E
P116E
P116E
P116E to select the zone
➋
Press 0E
0E
0E
0E
0E to clear the device
(3 beeps will sound)
TIP:
To prevent conflicting radio signals when programming Radio
Devices, disable each device once you have finished programming it.
(Remove the battery or open the RADIO link).
Remember to enable all the devices when programming is completed.
Technical Manuals Online! - http://www.tech-man.com