P R O G R A M M I N G
NESS D16 (V4.6) CONTROL PANEL - INSTALLER MANUAL
BRIEF MONITOR MODE ALARM
Alarms in Monitor Mode can either activate the programmed outputs for Siren
Time duration (P29E) or they can activate the outputs for 2 seconds only.
PROGRAMMING SEQUENCE:
P64E 1E
toggles the option ON and OFF
P64E 1E OFF: Brief Monitor Alarm disabled. Monitor Mode alarms have normal time as set by P29E
P64E 1E ON: Brief Monitor Alarm enabled. Monitor Mode alarms are ON for 2 seconds only
P64E 1E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
OFF: Brief Monitor Alarm disabled
• RELATED OPTIONS:
P51E
Set Monitor zones
P63E 1E-4E
Monitor Mode output
mapping
BRIEF DAY ALARM
Alarms in Day Mode will activate the programmed outputs while the zone is
unsealed or they can activate the outputs for 2 seconds only.
This option, when on, also enables the Temporary Day Zone feature. See page 19.
PROGRAMMING SEQUENCE:
P64E 2E
toggles the option ON and OFF
P64E 2E OFF: Brief Day Alarm disabled. Day alarm outputs are ON while the zone is unsealed
P64E 2E ON: Brief Day Alarm Enabled. Day alarm outputs are ON for 2 seconds only
P64E 2E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
OFF: Brief Day Alarm disabled
NOTES:
• RELATED OPTIONS:
P53E
Assign Day zones
P63E 5E-8E
Day Mode output mapping
MONITOR ZONES ENTRY DELAY 2
Monitor zones can either have the delay types set by options P40E-P43E or
they can all be assigned to have Entry Delay 2. This allows all Monitor zones to
be programmed with the same entry delay time.
PROGRAMMING SEQUENCE:
P64E 3E
toggles the option ON and OFF
P64E 3E OFF: Monitor zones behave as programmed by P40E-P43E
P64E 3E ON: Monitor zones all have Entry Delay2
P64E 3E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
ON: Monitor zones all have Entry Delay2
NOTES:
• RELATED OPTIONS:
P27E
Entry Delay Time 2
P51E
Assign Monitor zones
P63E 1E-4E
Monitor Mode output mapping
ARM/DISARM CHIRPS
If this option is selected the Siren and Strobe Outputs will "Chirp" when the
panel is Armed and Disarmed with the Keyswitch or Radio Keys.
The panel will make 1 Chirp on Arming, and 3 Chirps on Disarming.
PROGRAMMING SEQUENCE:
P64E 4E
toggles the option ON and OFF
P64E 4E OFF: No Arm/Disarm chirps
P64E 4E ON: Siren & Strobe outputs will chirp on arm/disarm
P64E 4E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
OFF: No chirps
NOTES:
• RELATED OPTIONS:
P68E 8E
Quiet Chirps
1E 2E 3E 4E 5E 6E 7E 8E
ON = Factory default setting.
2 second Monitor Alar
m
2 second Day Alar
m
Monitor zones Entr
y2
R
adio K
ey chirp & flash
50Hz mains frequencyDouble key K
eypad P
anic
K
eypad Fire Alar
m
K
eypad Medical Alar
m
OPTION No
DESCRIPTION
P64E
Miscellaneous options
ON ON
ON ON
Technical Manuals Online! - http://www.tech-man.com