P R O G R A M M I N G
NESS D16 (V4.6) CONTROL PANEL - INSTALLER MANUAL
1E 2E 3E 4E 5E 6E 7E 8E
ON = Factory default setting.
Disable dialler Contact ID for
mat
Audible DTMF for
mat
Audible PULSE for
mat
Contact ID + Audible DTMF
Contact ID + Audible PULSE
.
.
OPTION No
DESCRIPTION
P86E
Reporting Formats
ON
DISABLE DIALLER
This option disables the dialler even if telephone numbers and other dialler
options are programmed.
Up download or remote telephone access remain enabled.
PROGRAMMING SEQUENCE:
P86E 1E
turns the option ON
P86E 1E ON: Dialler disabled
P86E 1E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
Off: dialler enabled
NOTES:
• This option is useful for temporary
disabling of the dialler without affecting
other dialler options.
• Only one option in the range
P86E 1E—6E is allowed to be ON
CONTACT ID FORMAT
This option enables the reporting of alarms to a Central station via telephone
numbers 1 & 2 using Contact ID format.
PROGRAMMING SEQUENCE:
P86E 2E
turns the option ON
P86E 2E ON: Contact ID format enabled
P86E 2E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
ON: Contact ID format enabled
NOTES:
• Only one option in the range
P86E 1E—6E is allowed to be ON
AUDIBLE DTMF FORMAT
For Audible Monitoring to any telephone or mobile phone. The last digit of the
Account number and the zone alarm are sent in Audible DTMF format.
The message is repeated for 45 seconds or until kissed-off by the receiving
telephone.
PROGRAMMING SEQUENCE:
P86E 3E
turns the option ON
P86E 3E ON: Audible DTMF format enabled
P86E 3E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
OFF
NOTES:
• Only one option in the range
P86E 1E—6E is allowed to be ON
AUDIBLE PULSE FORMAT
For Audible Monitoring to any telephone or mobile phone. The last digit of the
Account number and the zone alarm are sent in Audible PULSE format.
The message is repeated for 45 seconds or until kissed-off by the receiving
telephone.
PROGRAMMING SEQUENCE:
P86E 4E
turns the option ON
P86E 4E ON: Audible PULSE format enabled
P86E 4E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
OFF
NOTES:
• Only one option in the range
P86E 1E—6E is allowed to be ON
• This is the best option to select for
Audible Monitoring.
Technical Manuals Online! - http://www.tech-man.com