P R O G R A M M I N G
NESS D16 (V4.6) CONTROL PANEL - INSTALLER MANUAL
ZONE TO OUTPUT MAPPING
When a zone alarms, it can turn on any or all of the following 6 outputs: Sonalert,
Strobe, Siren, Reset, AUX1, AUX2.
The programming is selected with options P54E - P59E. Simply set the zone
number to the output to select it. The zone LED will indicate if the zone is se-
lected.
The Tamper Input and the Keypad Panic can be programmed to turn on the Re-
set, Strobe, Sonalert and Siren by using option P61E.
P54E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
all ON: All zones trigger Reset output
NOTES:
•
0E
will turn all selections OFF
MEMORY E
will turn all selections ON
RESET OUTPUT ZONES
Selects the zones to trigger the Reset output.
PROGRAMMING SEQUENCE:
P54E [Zone No]E
toggles the options ON and OFF
P54E [Zone No]E OFF: The zone will not trigger the Reset output
P54E [Zone No]E ON: The zone will trigger the Reset output
P55E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
all ON: All zones trigger Strobe output
NOTES:
•
0E
will turn all selections OFF
MEMORY E
will turn all selections ON
STROBE OUTPUT ZONES
Selects the zones to trigger the Strobe output.
PROGRAMMING SEQUENCE:
P55E [Zone No]E
toggles the options ON and OFF
P55E [Zone No]E OFF: The zone will not trigger the Strobe output
P55E [Zone No]E ON: The zone will trigger the Strobe output
P56E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
all ON: All zones trigger Keypad Sonalert
NOTES:
•
0E
will turn all selections OFF
MEMORY E
will turn all selections ON
KEYPAD SONALERT ZONES
Selects the zones to trigger the Keypad Sonalert (beeper).
PROGRAMMING SEQUENCE:
P56E [Zone No]E
toggles the options ON and OFF
P56E [Zone No]E OFF: The zone will not trigger the Keypad Sonalert
P56E [Zone No]E ON: The zone will trigger the Keypad Sonalert
ZONE TO OUTPUTS MAPPING
ZONE TO OUTPUTS MAPPING
ZONE TO OUTPUTS MAPPING
ZONE TO OUTPUTS MAPPING
ZONE TO OUTPUTS MAPPING
OPTION No
DESCRIPTION
1
2
3
4
5
6
7
8
9
10
11 12
13 14 15 16
P54E
Reset zones
P55E
Strobe zones
P56E
Sonalert zones
P57E
Siren zones
P58E
Aux1 zones
P59E
Aux2 zones
Zones
ON = Factory default setting
ON
ON ON ON ON ON ON
ON ON ON ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
NOTE: Zone To Output Mapping
applies to zones when the panel is
in the Armed or 24hr state.
For MONITOR and DAY mode
Output Mapping - see Option
P63E 1E-8E, page 28