13
13
13
13
13
P R O G R A M M I N G
NESS D16 (V4.6) CONTROL PANEL - INSTALLER MANUAL
[INSTALLER CODE]
Factory default Installer Code: 000000
[MASTER CODE]
Factory default Master Code: 123
USER PROGRAM Mode
INSTALLER PROGRAM Mode
NORMAL OPERATING Mode
Power up with
Program Link OFF
(Usually on first time installation)
PROGRAM LIGHT IS FLASHING
PROGRAM LIGHT IS ON
PROGRAM LIGHT IS OFF
PROGRAM MODE LEVELS
TABLE 4.
TABLE 4.
TABLE 4.
TABLE 4.
TABLE 4. FLOW CHART
INSTALLER PROGRAM MODE
Installer Program Mode allows
access to ALL program options.
Note: The panel will remain in
Installer Program Mode indefinitely.
PROGRAM
PROGRAM
light
is FLASHING
USER PROGRAM MODE
User Program Mode allows the
owner to program:
• All User Codes
• Entry Exit Times
• Follow Me Telephone number
Note: The panel will automatically
drop out of User Program Mode to
Operating Mode if no keypad
buttons are pressed for 4 minutes.
PROGRAM
PROGRAM
light
is ON
HOW TO ENTER PROGRAM MODE
FROM POWER UP
1. Power-up with the PROG link OFF.
(The PROG link (or Box Tamper lead) must be ON in Operating Mode).
USING KEYPAD
The panel must be Disarmed.
1. Press
[MASTER CODE]
The keypad will respond with 3 beeps
This is User Program Mode (PROGRAM light is ON).
2. Press
[INSTALLER CODE]
The keypad will respond with 3 beeps
This is Installer Program Mode (PROGRAM light is FLASHING).
HOW TO EXIT PROGRAM MODE
1. Press
then
This is Operating Mode (PROGRAM light is OFF).
FACTORY DEFAULT
MASTER CODE: 123
INSTALLER CODE: 000000
PROGRAM
button
3 beeps
Selects a program
option (address)
The current value
is displayed
The keypad lights or
icons will display the
current value
Enter new
data
3 beeps
ENTER
button
ENTER
button
2 or 3 Digit Option
(00 to 119)
Enter new value
using keys 0 - 9
KEY SEQUENCE
IN PROGRAM
MODE
Technical Manuals Online! - http://www.tech-man.com