NESS D16 (V4.6) CONTROL PANEL - INSTALLER MANUAL
1E 2E 3E 4E 5E 6E 7E 8E
ON = Factory default setting.
Enable Output Expander
Alter
nate for
mat
Day zone followerOutput exclude .
.
.
.
OPTION No
DESCRIPTION
P117E
Output Expander options
ENABLE OUTPUT EXPANDER
Selecting this option enables the D16 Output Expander. When the Output
Expander is enabled, the outputs normally found on the panel’s J3 header will
be on the Output Expander/s. See the Alternate Format Table.
PROGRAMMING SEQUENCE:
P117E 1E
toggles the option ON and OFF
P117E 1E OFF: No Output Expander
P117E 1E ON: Output Expander enabled
P117E 1E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
OFF: No Output Expander
NOTES:
• Up to 2 Output Expander boards can be
used per D16 panel.
(Optional)
D16 OUTPUT EXPANDER
(100-699)
TO
J3 HEADER
D16 BOARD
1
9
2
10
3
11
4
12
5
13
6
14
7
15
8
16
OUTPUTS
OUTPUTS
NESS SECURITY PRODUCTS
D16 OUTPUT EXPANDER
J2
J1
RED
ALTERNATE EXPANDER FORMAT
Selecting this option changes the alarms on the 1st and 2nd Output Expander.
With the option OFF:
Zone 1 to Zone 16 are on the 1st Expander. The AUX, ARM
and other outputs are on the 2nd Expander. Use this option when only Zone
outputs are required and only one Expander is used.
With the option ON:
Zones 1 to Zone 8 are on the 1st Expander. The AUX, ARM
and other outputs are on the 1ST Expander. Zones 9 to Zone 16 are on the 2nd
Expander. Use this option when a variety of outputs are needed using only one
Expander.
PROGRAMMING SEQUENCE:
P117E 2E
toggles the option ON and OFF
P117E 2E OFF: No Alternate Format
P117E 2E ON: Alternate Format enabled
P117E 2E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
OFF: No Alternate Format
NOTES:
• The 2nd Expander plugs into the 6-way
header on the 1st Expander. This 6-way
header on the Expander cannot be used
for any other purpose.
• IF ALL 16 ZONES and the AUX outputs
are required then 2 Expanders are needed
- in which case select this option so that
it best suits the installation wiring.
P117E 2E = OFF
P117E 2E = ON
OUTPUT
OUTPUT
EXPANDER 1
EXPANDER 1
EXPANDER 2
EXPANDER 2
1
Zone 1
User Code 9
1
Zone 1
User Code 9
2
Zone 2
User Code 10
2
Zone 2
User Code 10
3
Zone 3
User Code 11
3
Zone 3
User Code 11
4
Zone 4
User Code 12
4
Zone 4
User Code 12
5
Zone 5
User Code 13
5
Zone 5
User Code 13
6
Zone 6
User Code 14
6
Zone 6
User Code 14
7
Zone 7
User Code 15
7
Zone 7
User Code 15
8
Zone 8
Tel. Line Fail
8
Zone 8
Tel. Line Fail
9
Zone 9
Arm Area 1
9
Arm Area 1
Zone 9
10
Zone 10
Arm Area 2
10
Arm Area 2
Zone 10
11
Zone 11
Aux 1
11
Aux 1
Zone 11
12
Zone 12
Aux 2
12
Aux 2
Zone 12
13
Zone 13
Arm Monitor
13
Arm Monitor
Zone 13
14
Zone 14
Mains Fail
14
Mains Fail
Zone 14
15
Zone 15
Battery Fail
15
Battery Fail
Zone 15
16
Zone 16
Ext. Tamper
16
Ext. Tamper
Zone 16
1
1
9
9
2
2
10
10
3
3
11
11
4
4
12
12
5
5
13
13
6
6
14
14
7
7
15
15
8
8
16
16
OUTPUTS
OUTPUTS
OUTPUTS
OUTPUTS
NESS SECURITY PRODUCTS
D16 OUTPUT EXPANDER
NESS SECURITY PRODUCTS
D16 OUTPUT EXPANDER
J2
J2
RED
RED
RED
J1
J1
TO J3 HEADER
D16 BOARD
Connecting Two Output Expanders