IDTeck – FINGER007 FINGERPRINT & PROXIMITY READER
“Door Closed”& CONTACT MASTER“ shows on LCD with buzzer sounds after card reading.
Cause
Of setting error, P/W deletion, defect of internal elements
Solution 1. Check the communication status. If the communication of the device with PC is normal
and this
problem occurs, check if the yellow LED is on in normal. If normally the yellow LED is
ON, the door
is locked by output time schedule setting.
2. If it is case of “1”check OUTPUT T/S or reinitialise the device. If the problem remains
after performing it, please contact Ness Service Office.
3. If it is not the case of “1”, no communication, its yellow LED light off, it is of saved P/W
deletion.
Please contact Ness service centre. CONTACT
www.ness.com.au
4. Of V4.5 or higher, in case of “3” it shows message “with buzzer sound when the power is
turn on.
A valid card became unregistered after batch-downloading IDs from PC.
Cause
Wrong procedure during download, or a component defect.
Solution 1.
The card ID might be registered only to the controller and not registered in PC. The
process of downloading IDs,
FINGER007
first erase the ID memory of the unit, therefore
if the IDs from the PC didn’t contain the card ID, this can happen.
2.
Check whether the card ID is registered in PC
3.
If not, please register the number and try downloading again.
If the trouble remains after the procedure above, contact a designated service centre.