IDTeck – FINGER007 FINGERPRINT & PROXIMITY READER
B. TROUBLE SHOOTING
Broken or abnormal letters show on the LCD, when powered on.
Cause
Of troubles of its battery in charge of the internal back-up or of circuits near around
Solution 1. Initialise the controller referring “hardware initialisation of the manual”
2. Set the current time in Set-Up menu of F1 and turn its power off and on again.
3. If the problem remains after performing 1, 2 of the above, please contact designated
service centre.
Unable to enter set-up mode with MASTER ID (default value:‘00000000’) and P/W(default
value: ’3141’)
(or. In case FINGER007SR, master ID consists 10digits character. Default ID “0000000000”)
Cause
Of internal element error, of unconsciously changed Master ID or of Set-up error
Solution 1. Check Master ID and Master P/W.
Try changing the RF_PIN_ENABLE setting to “ENABLE” through the application S/W.
Try changing the Master ID and P/W through the application S/W.
2. When it is not feasible, initialise the unit in the light of the manual.
Check Backup BAT S/W
(Mount hole in the reverse side. Of V4.70 or higher)
- It must be placed
“ON”
.
*
Note that all the value will be set to default, including the IDs after initializing.
3. If the trouble remains after the procedure above, contact a designated service centre.
Randomly changed value of in/out define from previously setting value after power reset.
Cause
Discharge of RAM Back-Up battery problem during the main power off.
Solution 1. Check Backup Battery Switch: It must be placed ON. (Of V4.70 or higher)
2. Check if the voltage of Back-Up Battery is over 3.6V..
3. If it is over 3.6V, make initialisation process as below.
- Turn off the system power and connect 3 wires (pink, cyan and black (GND)).
- Turn on the system power. Then you can enter system initialisation mode. Enter
<1>
key,
then system is initialising.
- After initializing, keep the main power on more than 5 days.
* Aware that all the setting value be back to the default value and data memory be
clear.
(ID data clear/Event data clear/ Time Schedule data clear etc.)
4. If after all the above, the problem remains, please contact a designated service centre.