![NESS ID TECK Finger007 User Manual Download Page 11](http://html.mh-extra.com/html/ness-id-teck/finger007/finger007_user-manual_1669391011.webp)
101-092 11
FINGER007
–
Version 4.0
IDTeck – FINGER007 FINGERPRINT & PROXIMITY READER
Aux Input 2
IN2
Green with White stripe
EXTRA READER
Wiegand Data0
DATA0
Pink
Wiegand Data1
DATA1
Cyan
RS232 INTERFACE
RS232-TX
TXD
Black with White stripe
RS232-RX
RXD
Red with White stripe
RS422 INTERFACE
RS422-TX(-) TX(-)
Yellow
RS422-TX(+) TX(+)
Grey
RS422-RX(-) RX(-)
Blue
RS422-RX(+) RX(+)
Brown
4. INSTALLATION TIPS & CHECK POINT
Installing the
FINGER007
is a relatively easy task. It can be installed with common hand tools and readily
available communications wire. This section provides information about wiring, wire runs and other information
to make the installation quick and easy.
4.1 CHECK POINTS BEFORE INSTALLATION
4.1.1 CABLE / WIRE
Good electrical connections will minimize the line losses and avoid damages to the
FINGER007
control
electronics. Use good quality and proper thickness of wire with durable insulation such as vinyl or PVC. It
may be faster and much economical to run multiple, twisted pair cable rather than individual pairs. The
following cable and wire thickness from the Belden Master Catalog 885 are adequate for the most
FINGER007
applications. These are offered as a reference only.
Belden No. 9745 3 twisted pairs, 22 AWG, 7/30 stranded, unshielded, PVC insulation and jacket,
14.7 ohms/1000 feet (about 300meter).
Belden No. 9750 3 twisted pairs, 20 AWG, 10/30 stranded, unshielded, PVC insulation and jacket,
10.3 ohms/1000 feet (about 300meter).
Belden No. 8303 3 twisted pairs, 22 AWG, 7/30 stranded, shielded, overall foil/braid shield, PVC
insulation and jacket, 14.7 ohms/1000 feet (about 300meter).
z
CONDUIT
The
FINGER007
does not normally require conduit. However, some location may require conduit for
wire protection. Check installation requirements and specifications for your site.
z
COMMUNICATIONS WIRING
FINGER007
communication is required for using twisted pair wires.
CAUTION :
Distance can be reduced by surroundings.
Cable Range between Host &
Finger007