NESS ID TECK Finger007 User Manual Download Page 5

 

 

101-092                                                                                          5         

                                   

FINGER007 

 Version 4.0 

IDTeck – FINGER007 FINGERPRINT & PROXIMITY READER

 

2.  INTRODUCTION 

 

 

2.1 IDENTIFYING SUPPLIED PARTS 
 

Please unpack and check the contents of the box. (Optional accessories, if purchased, may be included in 
the package) 

 

 

 
 

2.2 ABOUT NESS - IDTECK FINGER007 
 

The 

NESS - IDTECK FINGER007

 is a highly advanced, intelligent single door controller (network 

able) with a powerful 32bit and dual 8bit microprocessor to meet the market requirement for a robust 

integrated solution for access control and time & attendance. The unit is designed to be flexible and 

reliable as well as provide the ultimate in biometric high security at a reasonable cost. This user-friendly 

device allows you to register up to 720 fingerprint IDs (optional 2,000/4,500); add / delete user IDs 

conveniently; store up to 26,000 transactions in its event buffer; easily report and archive information to 

Excel or Access databases; and ultimately successfully manage all access control and time & attendance 

issues. With a built-in 4" RF reader, keypad for Personal Identification Numbers (PIN), and a 

sophisticated biometric fingerprint analyser, the 

FINGER007

 offers up to three levels of ID verification. 

Any combination of proximity (RFID), PIN, and biometric may be used and different verification levels 

can be custom programmed for each user or user group. Four independent inputs can be utilized for a 

wide variety of controls including exit buttons, door contacts, PIR sensors and fire detection equipment. 

Actions to be taken and time settings can be programmed with the front keypad or via the intuitive 

Windows based software program. The 

FINGER007

 can be used both as a stand-alone system and also 

be networked. All control setting values such as ID numbers, inputs/outputs, real-time clock, time 

schedules, and event transaction reports can be uploaded and/or downloaded to and from the host 

computer. The compact and contemporary unit is easily installed and programming requires no significant 

knowledge of access control or time & attendance. The Three-LED indicator lights inform you of the 

systems operating status at real time and the digital display acts as a programming aid as well as a 

regulation time clock. By bundling the ultimate in high security access control and comprehensive 

employee management tools into a compact user friendly unit, the field proven 

NESS - IDTECK 

FINGER007

 has made real what until recently was thought only to be possible in science fiction. 

Summary of Contents for Finger007

Page 1: ...IDTeck Finger007 Access Controller Rev V4 0 USER S MANUAL The specification contained in this manual are subject to change without notice at any time ...

Page 2: ...HECK POINT 4 1 CHECK POINTS BEFORE INSTALLATION 4 1 1 CABLE WIRE 4 1 2 TIPS FOR PLACING DEVICES 4 2 CHECK POINTS DURING INSTALLATION 4 2 1 TERMINATING RESISTANCE 4 2 2 DISCCORD OF ELECTRIC POTENTIAL 4 2 3 EARTH GROUND 4 3 TIPS TO MAXIMIZE READ RANGE OF RFID READERS 4 3 1 POWER SUPPLY 4 3 2 ENVIRONMENTAL SOURCES OF ELECTRICAL INTERFERENCE 5 INSTALLATION 5 1 TEMPLATE Wall Mount 5 2 BACKUP BATTERY S ...

Page 3: ... CONNECTIONS 6 3 DIAL UP MODEM 6 4 TCP IP CONVERTER EXTERNAL VERSION 7 BASIC SETTINGS 7 1 INITIALIZATION OF FINGER007 7 2 HOW TO ENTER THE SETUP MENU 7 3 DATE AND TIME SETTING 7 4 ID REGISTRATION 8 OPERATION 8 1 NORMAL OPERATION 8 2 DEFAULT SETTING 9 SETTING CHANGES 9 1 SETUP MENU F1 9 2 SETUP MENU F2 9 3 SETUP MENU F3 9 4 SETUP MENU F4 APPENDIX A THE RELATION BETWEEN INPUT AND OUTPUT DEFAULT B TR...

Page 4: ...unning The unit may not operate normally Do NOT set this product near heaters or any thing that produces heat There may be a risk of fire Be ALWAYS careful not to short circuit any part of the circuitry with tools like a screwdriver in hand There may be a risk of fire or heavy damage of the unit ON MAINTENANCE Do NOT use any kind of liquid for cleaning There may be a risk of electric shock fire or...

Page 5: ...007 offers up to three levels of ID verification Any combination of proximity RFID PIN and biometric may be used and different verification levels can be custom programmed for each user or user group Four independent inputs can be utilized for a wide variety of controls including exit buttons door contacts PIR sensors and fire detection equipment Actions to be taken and time settings can be progra...

Page 6: ...st Format for keypad reader Communication port RS232 RS422 up to 32 channels selectable 4800 9600 Default 19200 38400bps communication speed Input Output 4 Input ports DC12V 20mA 2 Relay Output ports DC12V FORM C Relay 2A max 2 TTL Output ports DC5V 20mA Keypad 16 Keypad Back lighting LCD 1 x LCD module 2Lines x 16ch 65 6 x 13 8mm view area Light source LED finger unit Mounting Wall mounted Colour...

Page 7: ...e data transmitted from the controller can be displayed and stored on the host PC Data Backup The controller retains all user information and event data for 30 days even in the event of power failure CAUTION Battery S W must be set correctly before the unit running See the INSTALLATION section Keypad If the NESS IDTECK FINGER007 is not connected to host PC the integrated keypad and LCD display mod...

Page 8: ... zone of time schedule Example A Holiday schedule 01 linked to time schedule 01 Holiday schedule 02 linked to time schedule 02 B Holiday schedule 02 linked to time schedule 01 Holiday schedule 01 linked to time schedule 02 Forced Door Open and Door Open Too Long Alarm When a door is opened by force the Door Contact Output is generated And when the door is opened by normal operation and not closed ...

Page 9: ...tion ratio When using this mode you have to press the ENT key first then the fingerprint scanner waits for a fingerprint to be scanned When a fingerprint scanning is completed FINGER007 compares the data and makes corresponding outputs z FINGER007 of V4 75 or higher has a sensor finger detect So in identification mode you need not enter ENT key If you touch at finger sensor then Finger007 detects ...

Page 10: ...2 2 COLOUR CODED WIRING TABLE IO PORT NAME SIGNAL NAME COLOUR CODED POWER Main Power 12V 12V RED Power Ground GND BLACK OUTPUT Door Relay COM COM 1 Grey with Red stripe Door Relay NC NC 1 Blue with White stripe Door Relay NO NO 1 White with Red stripe Alarm Relay COM COM 2 White Alarm Relay NC NC 2 Purple with White stripe Alarm Relay NO NO 2 Purple TTL Output1 TTL1 Orange with White stripe TTL Ou...

Page 11: ...ith durable insulation such as vinyl or PVC It may be faster and much economical to run multiple twisted pair cable rather than individual pairs The following cable and wire thickness from the Belden Master Catalog 885 are adequate for the most FINGER007 applications These are offered as a reference only Belden No 9745 3 twisted pairs 22 AWG 7 30 stranded unshielded PVC insulation and jacket 14 7 ...

Page 12: ...ange between Finger007 Lock Finger007 Alarm device Cable Standard LOCK ALARM Standard 1 25mm 90m 90m UL 0 75mm 60m 60m UL 0 3mm 30m 30m UL CAUTION Install a surge absorber or reverse surge protector diode at any relay contact that switches DC voltages to an inductive load 4 1 2 TIPS FOR PLACING DEVICES z FINGER007 EXIT READER CARD READER Select a site to be found easily by users Prevent it from ex...

Page 13: ...ethod put terminating resistance in order to decrease noise of the communication cable It helps data communication when there is noise 100 120Ω may be used Connect the resistance the first and last device connected in the line CAUTION In case that use terminating resistance signal level as well as noise is decreased too Use properly fit in communication environment 4 2 2 DISACCORD OF ELECTRIC POTE...

Page 14: ...e grounding for communication cable it must be less than 10Ω 4 3 TIPS TO MAXIMIZE READ RANGE OF RFID READERS 4 3 1 POWER SUPPLY z Use linear series pass power supplies Switching power supplies may reduce the read range z Use a separate dedicated power supply for each reader Do not use the reader s power supply for other equipment particularly when operating switched inductive loads such as motor c...

Page 15: ...he Wall Mount bracket as shown below If the gang box is already installed on the wall then skip this step Using 2 screws install wall mount to the wall CAUTIONS Before mounting the NESS IDTECK FINGER007 unit to the Wall Mount bracket an operational test of the unit should be completed because the locking pins will lock the unit to the Wall Mount Removing the unit from the Wall Mount bracket after ...

Page 16: ...EM INITIALIZATION Extra Reader Port You must operate H W initialization before the FINGER007 installation Of V4 70 or higher you must connect battery backup S W in reverse side before H W initialization You can H W initialize using extra reader port First turn off the system power and connect 3 wires pink cyan and black GND and turn on the system power Then you can hear Initialize beep and display...

Page 17: ...nput Connection Applied IN1 IN2 Connect one wire from an Auxiliary Input Device to one of the IN1 Green wire IN2 Green with White stripe Connect the other wire from the Auxiliary Input Device to GND Black wire Figure INPUT DEVICES CONNECTION 5 4 3 OUTPUT CONNECTIONS Door Lock Power Fail Safe Connection Relay 1 Connect COM port of Relay 1 to 12V Connect NC port of Relay 1 to wire of door lock devic...

Page 18: ...ire Connect Data 0 wire of the Proximity Reader to DATA0 Pink wire Connect DATA 1 wire of the Proximity Reader to DATA1 Cyan wire Compatible Readers Extra Reader FINGER007 iPFINGER007 Standard 26bit Wiegand Format Proximity Readers Standard 26bit Wiegand 8bit Burst Format Proximity and keypad Reader FINGER007SR Standard 34bit Wiegand Format Proximity Reader Standard 34bit Wiegand 8bit Burst Format...

Page 19: ...the host PC Install and run FINGER007 Application Software 6 2 RS 422 COMMUNICATION PORT CONNECTION 6 2 1 RS 422 CONNECTION STAND ALONE RS422 RS232 converter CNP200 is required to use RS422 communication between the FINGER007 and a host computer Please follow the instructions Connect RS422 TX of the FINGER007 to RS422 RX port of the converter Connect RS422 TX of the FINGER007 to RS422 RX port of t...

Page 20: ...ther FINGER007 Connect RS422 RX of one FINGER007 to RS422 RX of another FINGER007 Second you have to connect one of RS422 port of FINGER007 to RS422 RS232 converter Connect RS422 TX of the one FINGER007 to RX port of the converter Connect RS422 TX of the one FINGER007 to RX port of the converter Connect RS422 RX of the one FINGER007 to TX port of the converter Connect RS422 RX of the one FINGER007...

Page 21: ...T SYSTEM INITIALIZE RF_PIN_ENABLE SETTING YES YES NO NO WAITING REBOOT INITIAL BEEP SYSTEM READY GENERAL BOOT In the system ready LCD display model name current date and time ID INPUT NO YES MASTER ID YES ENTER SETUP MENU END SETTING REGISTERED ID CHECK REGISTERED ID S FLAGS RIGHT OUTPUT CONTROL OF EACH STATUS NO YES YES NO NO NO SETTINGIN SETUP MODE You can select output of each status in setup m...

Page 22: ... Default setting 3141 then you can get into SETUP MENU There are 4 main SETUP MENU and you first get into SETUP MENU F1 You can move to other SETUP MENU by pressing F1 key for SETUP MENU F1 F2 key for SETUP MENU F2 F3 key for SETUP MENU F3 and F4 key for SETUP MENU F4 There are several SUB MENU in the main SETUP MENU and you can scroll up and down the SUB MENU by pressing 4 and 6 key in the main S...

Page 23: ...r Min Sec Day Æ Day code 1 Sun 2 Mon 3 Tue 4 Wed 5 Thu 6 Fri 7 Sat For example 200106071330253 for Tuesday June 7 2001 01 30 25PM 7 4 ID REGISTRATION You can register the User ID into FINGER007 Select SETUP MENU F3 Æ ID REGISTRATION then follow the steps below The Master ID for FINGER007SR is 10 digits number Default setting 0000000000 ID REGISTRATION ENT ID REGISTRATION Select ID Registration men...

Page 24: ...int FP 1 Input fingerprint first time False Success Input fingerprint second time False Input PW TS RD FP Success 3 After ID Registration complete return initial display by enter ESC Key 4 When register more than one ID register first ID and continuously register other IDs 5 If the ID number has a fingerprint already in case of re registration the current fingerprint should be scanned first 6 You ...

Page 25: ... not access through the Main and Extra Reader and FINGER007 generates an error message Access Door Error and displays on the LCD To get access through all Readers you have to input 3 value for RD The FP is for using fingerprint If 1 is entered for the value the user has to register fingerprint And the user certification of fingerprint in RF Finger P W and RF P W Finger mode If 0 is entered for the...

Page 26: ..._PIN_INPUT E SELECTION ME SETTING PE SELECTION PB SETUP OMM ID SETTING DURESS MODE SET AUD RATE VENT CLEAR STER ID CHANGE YS INITIALIZE 1 TIME SCHEDULE 2 HOLIDAY T S 3 IN OUT DEFINE 4 HOLIDAY INDEX 5 MODE INDEX 6 LCD DISPLAY 7 OUTPUT TIME 1 ID REGISTRATION 2 ID DELETE 3 ID LIST 4 ID COUNT 5 EVENT COUNT 1 F W VERSION 2 SRAM TEST 3 OUTPUT TEST 4 LCD TEST 5 KEYPAD TEST 6 READER TEST 7 INPUT TEST 8 CO...

Page 27: ...y then FINGER007 will exit the SETUP MENU and return to normal operation The Master ID for FINGER007SR is 10 times 0 key Default setting 9 1 SETUP MENU F1 MODE SELECTION TIME SETTING TYPE SELECTION STAND ALONE USE NOT USE USE NOT USE APB SETUP NOT USE USE ALL CLEAR RF Only ID Only RF FINGER P W ID FINGER P W RF P W FINGER ID P W FINGER FINGER007P COMM ID SETTING Seach Key 4 6 Seach Key Seach Key S...

Page 28: ... NO MASTER ID CHANGE SYSTEM INITIALIZE YES NO ID CLEAR YES NO TIME SCHE CLEAR YES NO DISA M ODESELECTION RF FINGER P W ID FINGER P W RF Only ID Only ENT SeachKey 4 6 SeachKey RF_PIN_INPUT ENABLE BLE Seach Key Seach Key Seach Key Seach Key Seach Key Seach Key Seach Key Seach Key DURESS P W USE Seach Key 9 1 1 READER MODE SETTING RF P W FINGER ID P W FINGER ...

Page 29: ...LECTION This Menu is to select operating mode You can choose whether to use password or fingerprint to each access or not The lower line on the LCD indicates the current operating mode Press ENT key to change the mode MODE SELECTION 9 1 2 TIME SETTING Enter the correct information of the year month date hour minute second day code in due order then the setting is finished If the input information ...

Page 30: ... shifts automatically to this menu NOTE If you use FINGER007P then you have to change setting to USE USE FINGER_007P After FINGER007P setting shifts automatically to this menu NOTE In DUAL FINGER MODE you can register two fingerprint per one ID But dual mode fingerprint data cannot be used for single mode system USE DUAL FINGER USE ADAPTIVE After DUAL FINGER setting shifts automatically to this me...

Page 31: ...only once You can select whether the anti pass back APB mode is used or not To change mode press ENT key It only applies when the Door has Exit Reader APB SETUP APB SETUP APB SETUP 9 1 5 COMMUNICATION ID ADDRESS DISPLAY 9 1 5 When the cursor is blinking enter a new ID Two Digit number then the setting is completed Possible ID is between 00 31 inclusive COMM The number on the LCD is the current com...

Page 32: ...whether the Duress mode is used or not To change mode press ENT key If you select USE then system display current DURESS P W To change P W press ENT key NOTE You can setting duress output in set up menu F2 in out define In case of Duress enter the 2 digit Duress Password and press ENT and open the door using general process If you registered ID then duress output will be generated DURESS P W DURES...

Page 33: ...TE 9 1 8 EVENT CLEAR You can clear the event memory in this menu Press ENT key then press 1 key to clear event memory or 0 key to cancel the operation CAUTION Before you clear the events make sure that the stored events is not necessary to upload to the host PC otherwise you may lose important data EVENT CLEAR EVENT CLEAR 9 1 9 MASTER ID CHANGE If you select 2 Key FINGER007 is waiting for a keypad...

Page 34: ...its and finish changing Master ID Master Card The figure indicates that changing Master ID is finished successfully and soon will return to the first figure of this menu Put Master FP A fingerprint for the new Master ID is needed to be scanned If there has been a Master ID already the fingerprint of the ID should be scanned first ...

Page 35: ...operation will initialise the FINGER007 Press ENT key if an initialisation is needed First time installation or resetting in the event of a malfunction After the initialisation FINGER007 will return to the set up menu CAUTION Initialising will erase all stored data in the memory ID EVENT T S In Out define etc Card ID Clear CARD ID CLEAR When you want to delete all User ID Card ID you can clear all...

Page 36: ...101 092 36 FINGER007 Version 4 0 IDTeck FINGER007 FINGERPRINT PROXIMITY READER 9 2 SETUP MENU F2 ...

Page 37: ...en the lower line will indicate the defined period For more schedules repeat the process To end time scheduling press ESC key You may program time schedules to grant and restrict access for each user There can be up to ten different schedules A minimum of one schedule must be defined If only one schedule is programmed the most common setting allows access for all users 24 hours day A time schedule...

Page 38: ...ex for the days 1 32 Then press ENT key and the cursor will blink then enter the date in the form of Month 1 12 date Then the LCD will indicate the defined date Now a day has been registered For further registration repeat the process You can register up to 32 specified holidays per year for each schedule setting There can be 10 other registration sets created meaning holidays can be set for up to...

Page 39: ...cess To end defining inputs outputs press ESC key and you will see the first figure of the menu NOTE The five couples of digit of 15 Output T S and 16 Input Output T S are time sched le inde es You can program or deactivate each output to be generated and choose how long in seconds they will last There are default values as seen in the table 2 below IN OUT DEFINE 1 Exit Button 9 2 4 HOLIDAY INDEX ...

Page 40: ...his is LCD display setting menu You can select whether LCD form is STATUS or CARD number STATUS Display status of reading ID CARD NO Display reading ID number LCD DISPLAY LCD DISPLAY 9 2 7 OUTPUT TIME UNIT SETTING This menu is to define time unit of 5 output ports 1 SEC Define time of output by second in the in out define 0 1 SEC Define time of output by 0 1 second 100ms in the in out define Eg In...

Page 41: ... COUNT SELECT REGISTRATION METHOD FINGER007 Search key Search key Search key Search key Search key CARD KEY ENTER ID NUMBER 4 8 digits FINGER007P KEY CARD or ID INPUT KEY PAD FINGER007 CARD KEY ID INPUT KEY PAD FINGER007P KEY DISPLAY ID PW TS DOOR and FINGERPRINT FLAG DISPLAY REGISTERED ID COUNT EVENT COUNT DISPLAY STORE EVENT COUNT ...

Page 42: ...r KEY ENTER NEW ID 4 8 Digits KEY CARD PRESENT CARD FINGER007P MASTER ID DISPLAY ERROR NO INPUT P W T S DOOR and FINGERPRINT flag USE FINGERPRINT YES ALREADY EXIST ID YES CERTIFICATION ID s FINGERPRINT SUCCESS YES REGISTRATION NEW ID s FINGERPRINT First time NO NO NO SUCCESS NO YES REGISTRATION NEW ID s FINGERPRINT Second time SUCCESS NO YES COMPLETION ID REGISTRATION YES ...

Page 43: ...ster 4 8 digits ID CAUTION Under V4 60 In case register by keypad you have to enter only 4digits ID This figure appears indicating the ID number you just entered on the upper line and you are to enter the following information for the ID number Four digit password two digit Time Schedule number Reader number see the NOTE below and FP flag enter 1 to register a fingerprint 0 not to If you enter 0 f...

Page 44: ... ID DELETE ID DELETE Enter Card No ID Deleted This is registered ID Deletion menu To delete some registered IDs press ENT key Enter the ID number or preset the card that you want to delete IDDELETE INPUT ID or APROACH CARD FINGER007 INPUT ID FINGER007P ENT SUCCESS DISPLAY ERROR YES NO ...

Page 45: ...r code and fingerprint flag are displayed on the LCD and you can scroll up and down the list by pressing 4 and 6 keys Press ESC key to return to the set up menu ID LIST TOP message will be displayed first when the first registered user ID is displayed on the LCD ID LIST BOTTOM message will be displayed first when the last registered user ID is displayed on the LCD ID List TOP ID List BOTTOM This m...

Page 46: ...EYPAD TEST Search key Search key Search key Search key Search key SRAM TEST OUTPUT TEST LCD TEST KEYPAD TEST READER TEST READER TEST FINGER007 DO NOT USE THIS MENU FINGER007P INPUT TEST INPUT TEST COMM TEST COMMUNICATION TEST RS 232 GET GAIN IN FDA CHECK FINGERPRINT DARKNESS SET GAIN IN FDA SET FINGERPRINT DARKNESS Search key Search key Search key Search key Search key ...

Page 47: ... and green LED This test is applicable to Relay2 and green LED This test is applicable to TTL1 0V 5V This test is applicable to TTL2 0V 5V This test is applicable to Buzzer The version of the controller s firmware is displayed on the LCD Press 4 or 6 key to look for other menus of set up menu F4 F W Version RAM test pass Memory fail SRAM TEST To test the SRAM memory press ENT key If the SRAM has p...

Page 48: ...ormance of the reader press ENT key NOTE In case FINGER007P this option is not applicable The reader is waiting for an RF card to read Present an RF card to the reader The test has completed successfully if the LCD displays the ID card number example shown to left OUTPUT 5 OUTPUT TEST To test the output performances press ENT key If the output performance has no problems the test will proceeds as ...

Page 49: ...re this communication test connect the RS 232 RX TX wires to each other If there is a problem with the communication performance check connections and try again As the test proceeds you can see the characters being transmitted and received Finally LCD display communication test pass message COMM test pass TX data 0 GET GAIN in FDA You can see the current fingerprint darkness for scan The gain is t...

Page 50: ...1 Exit button 5 Tamper S W operation is to be applied Index No Relay 1 Relay 2 TTL1 TTL2 BUZZER 1 Exit Button 03 00 00 00 00 2 Door Contact 00 03 03 03 03 3 AUX 1 00 03 03 03 03 4 AUX 2 03 00 03 03 03 5 Tamper S W 00 99 99 99 99 6 Reader1 ID OK 03 00 00 00 00 7 Reader1 ID Error 00 03 00 00 00 8 Reader1 ID T S Error 00 03 00 00 00 9 Reader1 APB Error 00 03 00 00 00 10 Reader2 ID OK 03 00 00 00 00 1...

Page 51: ... When it is not feasible initialise the unit in the light of the manual Check Backup BAT S W Mount hole in the reverse side Of V4 70 or higher It must be placed ON Note that all the value will be set to default including the IDs after initializing 3 If the trouble remains after the procedure above contact a designated service centre Randomly changed value of in out define from previously setting v...

Page 52: ...CCESS DOOR ERROR message shows If RD is set as 3 reader 1 2 both opens each door 3 Use software for time schedule setting in case it is connected to PC as the software manual 4 If the trouble remains after checking the above contact a designated service centre SCHEDULE ERROR message shows when RFID card is read Cause Error in RFID card registration time schedule setting or the system itself Soluti...

Page 53: ...eters at the S W should be set as follows Parity bit NONE Data bit 8bit Stop bit 1bit 2 Check the line connection for communication 3 In case of setting RS422 communication recommend to use line end resistors of 120 Ohm between the RX and RX lines and between the TX and TX lines and apply the same resistors to the converter RS422 lines Consult a service centre or an electric technician if you cann...

Page 54: ...not respond properly such as displaying wrong card numbers in the reader test mode Cause Reader defect wiring error between the reader and the controller or the electric noises around Solution 1 Be sure that the reader reads the card ID when you present a card 2 Be sure that the reader format is correct 26bit Wiegand or 34bit Wiegand for FINGER007SR 3 Check the wiring between the reader and FINGER...

Page 55: ...rprint error shows in the LCD repeatedly during fingerprint registration Cause Of that fingerprint is damaged fingerprint is extremely dried or the fingerprint module is defective of the device Solution 1 Of fingerprint registration it read a fingerprint twice If the first one and the second one are perfectly accord its registration fails After the first fingerprint reading take the finger out and...

Page 56: ...t is not the case of 1 no communication its yellow LED light off it is of saved P W deletion Please contact Ness service centre CONTACT www ness com au 4 Of V4 5 or higher in case of 3 it shows message with buzzer sound when the power is turn on A valid card became unregistered after batch downloading IDs from PC Cause Wrong procedure during download or a component defect Solution 1 The card ID mi...

Page 57: ...ts for a Class A Digital Device pursuant to Part 15 of the FCC Rules These limits are designed to this equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment do...

Page 58: ...www ness com au email ness ness com au NSW 4 167 Prospect Hwy Seven Hills NSW 2147 Ph 02 8825 9222 Fax 02 9674 2520 sales ness com au Vic 24 Terracotta Drive Blackburn Vic 3130 Ph 03 9875 6400 Fax 03 9875 6422 nessmelb ness com au QLD Unit 3A 471 Lytton Road Morningside Qld 4170 Ph 07 3399 4910 Fax 07 3217 9711 nessbris ness com au W A Unit 1 567 Newcastle Street Perth W A 6000 Ph 08 9328 2511 Fax...

Page 59: ...101 092 59 FINGER007 Version 4 0 IDTeck FINGER007 FINGERPRINT PROXIMITY READER ...

Page 60: ...101 092 60 FINGER007 Version 4 0 IDTeck FINGER007 FINGERPRINT PROXIMITY READER TEMPLATE ...

Page 61: ...101 092 61 FINGER007 Version 4 0 IDTeck FINGER007 FINGERPRINT PROXIMITY READER ...

Reviews: