![NESS ID TECK Finger007 User Manual Download Page 40](http://html.mh-extra.com/html/ness-id-teck/finger007/finger007_user-manual_1669391040.webp)
101-092 40
FINGER007
–
Version 4.0
IDTeck – FINGER007 FINGERPRINT & PROXIMITY READER
9.2.5 READER TIME SCHEDULE SETTING
☞
. If You set-up RF+FINGER(P/W) operating mode (Refer to MODE
SELECTION), you can apply Time Schedule for MODE INDEX. During the
time period of Time Code in the T/S,
FINGER007
will operate RF ONLY
mode. And the rest of time period,
FINGER007
will operate
RF+FINGER(P/W) mode.
To apply this function, you have to set-up Time Schedules (T/S) and
Holiday Schedules (H/S).
Select MODE INDEX then press
<ENT>
key. Enter 2 digit T/S index (‘00’ ~
‘10’).
MODE INDEX
MODE INDEX
9.2.6 LCD DISPLAY FORM SETTING
☞
. This is LCD display setting menu. You can select whether LCD form is
STATUS or CARD number.
•
STATUS
: Display status of reading ID.
•
CARD NO
: Display reading ID number.
LCD DISPLAY
LCD DISPLAY
9.2.7 OUTPUT TIME UNIT SETTING
☞
. This menu is to define time unit of 5 output ports.
1 SEC: Define time of output by second in the in/out define.
0.1 SEC: Define time of output by 0.1 second (100ms) in the in/out define.
Eg) In order to have the relay 1 operate for 3 second, responding to the exit
button input, set as follow.
- Define 1 Exit & Relay as “03” in IN/OUT define
- Define the OUTPUT TIME SET as 1 SEC.
Eg) In order to have the relay 1 operate for 0.3 second, responding to the
exit button input, set as follow.
- Define 1 Exit & Relay as “03” in IN/OUT define
Define the OUTPUT TIME SET as 0 1 SEC
OUTPUT TIME
OUTPUT TIME