Neomatica LLC. Vehicle tracker ADM333BLE GLONASS/GPS. Ver. 1.2  dd 13.07.2019

 

 

31 

7.2 Selecting data to be transmitted to the server from ADM31/32 sensors  

 

Depending on the functionality use of the BLE sensors ADM31/32, it is possible to disable the 

transmission of unnecessary fields to the server. Correspondence of the fields to parameter values 

of 

BLEPROTOCOL

 command is given in table 5. If you want to transmit data from several packets, 

the X parameter of the 

BLEPROTOCOL X

 command is calculated by addition. It is possible to use 

any options. 

Transmission of all fields are set by default.  

To save the traffic activate only the transmission of necessary fields.  

 

Table 5. Value of BLEPROTOCOL parameter 

Data packet 

Fields name at the server  

Parameter value  

All data   

 

255 

Temperature/Angle 

CAN1, CAN6, CAN11, CAN16, CAN21 

Humidity 

CAN2, CAN7, CAN12, CAN17, CAN22 

Illumination 

CAN3, CAN8, CAN13, CAN18, CAN23 

Battery voltage 

CAN4, CAN9, CAN14, CAN19, CAN24 

Hall sensor 

CAN5, CAN10, CAN15, CAN20, CAN25 

16 

 

7.3 Selecting the transmission format of the illumination level  

 

To save the traffic consumption a shortened range of illumination level values is transmitted by 

default. In case of necessity to use full range, activate it. Setting is done by 

LIGHTPROTOCOL X 

command. 

 

LIGHTPROTOCOL

 X 

X = 0,1 

– transmission format of illumination values 

 

– shortened value format:  

Discreetness: integer value  

Values range: 0...65534.  

Sensor data greater than 65534 are considered to be equal to this value.  

65535 value is considered as an error code 

«no signal from sensor». 

 

– full value format  

Summary of Contents for ADM333 BLE

Page 1: ...Neomatica LLC Vehicle tracker ADM333BLE GLONASS GPS Ver 1 2 dd 13 07 2019 1...

Page 2: ...parking 18 5 8 1 Coordinates fixation according to ignition 18 5 8 2 Coordinates fixation according to vibration level 18 5 9 Operation mode 19 5 9 1 Tracker operation mode 19 5 8 2 Beacon operation...

Page 3: ...33 9 Updating tracker software 43 9 1 Updating tracker software via ADM Configurator 43 9 2 Updating tracker software via ADM Configurator using a firmware file 43 9 3 Updating the tracker software v...

Page 4: ...vehicles and who have special professional knowledge in electronic and electric equipment used on various transport means The tracker proper work can be guaranteed if it is installed and set by qualif...

Page 5: ...PRS to a dedicated server with a static IP address or domain name from which it can be received via the Internet for further analysis and processing in a monitoring center The tracker can be configure...

Page 6: ...blishes connection with the server After connection to the server the tracker transmits the data packets with the pre set frequency or when an event occurs If for any reason the connection to the serv...

Page 7: ...ctor 1 Characteristics of discrete output of open collector type maximum voltage 45V maximum commutated current 100mA Acceleration meter digital triaxial Battery Li Pol 250 h 3 7V 0 9 W h Number of ro...

Page 8: ...Bluetooth unit of the combined module provides connection to the PC wireless information exchange between the tracker and the ADM Configurator as well as data receipt from wireless sensors To display...

Page 9: ...the other side of the housing at the angle of 45 degrees until the housing starts splitting 4 Take off the lower part of the housing 5 Bending two latches of any side of the housing lift the scheme up...

Page 10: ...ctivated PIN code request activated data transmission service via GPRS SMS and sufficient balance for these services Supply the power to the tracker according to the layout in Figure 3 and the scheme...

Page 11: ...connection mode To do this you need to select the way to connect the device by clicking on the Bluetooth icon in the upper left corner of the ADM Configurator as shown in Figure 4 4 Supply power to th...

Page 12: ...for any way of transmission General rules of writing and sending commands only Latin characters and punctuation can be used in commands character case does not matter commands transmission syntax is t...

Page 13: ...not required The tracker receives the commands from the server via TCP connection that is used for data transmission 5 3 Configuring SIM Enter parameters of the access point name APN in the ADM Confi...

Page 14: ...transmission of the necessary data packets The setting is done in the graphic interface of the ADM Configurator or by PROTOCOL command Table 1 shows the correspondence of data packets to the values o...

Page 15: ...total list of set parameters will be displayed Answer example TRACK 4 1000 100 1 3 5 2 3 5 3 3 5 Command without parameters displays current route settings Presets description TRACKSET 0 Satisfactory...

Page 16: ...d with four parameters Command format TRACK 255 X Y Z Setting the degree of road turns drawing detalization Setting threshold values of angle change and deflection A route point is drawn when the thre...

Page 17: ...e equal to 255 For all speed modes these parameters are the same X minimum speed Y distance meters Z acceleration km h per second Viewing set parameters TRACK Display current settings The response dis...

Page 18: ...ault It is impossible to use simultaneously two ways of coordinates fixation The tracker fixes the coordinates according to the last mode 5 8 1 Coordinates fixation according to ignition To enable the...

Page 19: ...ate draw exact path of travel The routes record is done using all possible criteria change of speed acceleration threshold exceeding distance passage direction change regarding the period of movement...

Page 20: ...the INTRUE and for the logical 0 with INFALSE Description of the commands INFALSE IN X0 Y0 IN number of the analog input always specify 0 X0 the lower limit of the logical 0 voltage range fixed value...

Page 21: ...e output is connected to the minus of the tracker external power supply Connection should be done according to the scheme in Figure 9 Figure 9 Scheme of the connection of charge with the current consu...

Page 22: ...he tracker output from self induction pulses which appear after switching off the inductive load including the relay coil it is necessary to connect a diode parallelly to the relay coil in the opposit...

Page 23: ...onfigurator graphical interface or by sending commands to the tracker via Bluetooth GPRS or SMS Up to 5 ADM31 32 sensors and 3 BLE fuel level sensors can be connected simultaneously to one tracker The...

Page 24: ...the sensors of the indicated type will be added Table 2 shows the correspondence of values to the BLE sensors types In case several sensors types should be bound simultaneously then add several needed...

Page 25: ...BLEAUTOCATCH D R T 6 3 3 Adding sensors ADM31 ADM 32 in manual mode viewing added sensors list The BLESENSOR command allows to add sensor addresses as well as to view the list of added addresses The s...

Page 26: ...T 300 00 L 655 35 H 255 R 0 LMT 0 S 32768 Description of answer parameters Fields general for all types of sensors ADM3x Sensor address DT type of the device PT type of the packet F software version V...

Page 27: ...R sensors list Parameters A and B limits of the acceptable illumination range Parameters A and B can be omitted current range will be displayed Setting upper and lower sensor states When there is a ch...

Page 28: ...ters displays the data from all set sensors Answer example BLEFUELINFO 0 0018E9C64433 DT 4 F 7 L 27 T 23 DTC 0 LMT 5 R 67 Decoding of the answer for ESCORT TD BLE DT device type T temperature L fuel l...

Page 29: ...Sensor 2 Sensor 3 Sensor 4 Parameter can1 can6 can11 can16 can21 Temperature can2 can7 can12 can17 can22 Humidity can3 can8 can13 can18 can23 Illumination level can4 can9 can14 can19 can24 Battery vol...

Page 30: ...illumination level Shortened format by default There is no need for conversion in case of using a shortened format Acceptable values range is 0 65534 65535 value is considered as an error code no sig...

Page 31: ...of BLEPROTOCOL parameter Data packet Fields name at the server Parameter value All data 255 Temperature Angle CAN1 CAN6 CAN11 CAN16 CAN21 1 Humidity CAN2 CAN7 CAN12 CAN17 CAN22 2 Illumination CAN3 CAN...

Page 32: ...hicle tracker ADM333BLE GLONASS GPS Ver 1 2 dd 13 07 2019 32 Discreetness two decimal places Values range 0 00 83865 60 42949672 95 value after formula calculation is considered as an error code no si...

Page 33: ...y via SMS Example ADD ME 1234 ADD ME 1234 2 PHOES 0 1 2 3 Example PHONES 0 7xxxxxxxxxx 1 2 3 PHONES 0 1 2 7xxxxxxxxxx 3 X password the default is 0 Y 0 3 number of the memory cell to store the number...

Page 34: ...sword Change the password from the old X to the newY The password is a number from one to eight digits 5 STATUS Example ID 1 Soft 0x1A GPS 9291 Time 11 21 39 25 02 10 Nav 0 Lat 57 2359 Lon 56 2593 Spe...

Page 35: ...123456789 SN X Example SN 123456789 X settable tracker ID Set the tracker ID 8 PIN0 X Example PIN0 1234 PIN0 X Example PIN0 1234 X pin code of Sim card Set the PIN code of the SIM card 9 PIN1 X Examp...

Page 36: ...X internet beeline ru Y login default Y beeline Z password default Z beeline Set APN settings for the SIM card A command without parameters returns the current GPRS settings for the SIM card 1 14 SET...

Page 37: ...e server for points grouping 19 ERASE FLASH ERASE FLASH Command without parameters Erase all information packets stored in the memory After executing this command the current information packet number...

Page 38: ...nput number always 0 Y minimum range limit in mV Y 60000 the maximum range limit in mV unchanged value Set the voltage range of the logical 1 in the analog input 24 InFalse X Y Y Example InFalse 0 0 4...

Page 39: ...TATIC 10 ACCELSTATIC X Y Z Example ACCELSTATIC 10 X timeout to enable static mode in seconds X 255 disabled function Y acceleration threshold to get out from static mode mg Z timeout to get out from s...

Page 40: ...racker detailed description in clause 6 3 3 Adding sensors ADM31 ADM32 in a manual mode and viewing the list of added sensors 34 BLESENSORINFO X BLESENSORINFO 0 D8A05B9BEF5B DT 1 PT 3 F 5 V 3 0 T 25 3...

Page 41: ...the upper sensor state Set the range of lower and upper state of the sensor 39 ALARMPERIOD X ALARMPERIOD X X time in seconds Set the period of information packets in an alarm mode 40 BLEFUEL X Y X cel...

Page 42: ...be transmitted Set the data set to be transmitted from sensors ADM31 32 detailed description in clause 7 2 Selecting data to be transmitted to the server from sensors ADM31 32 43 LIGHTPROTOCOL X X 0 s...

Page 43: ...date available 3 in the opened Notifications tab click Update 4 after the update the tracker will reboot and become available for operation ATTENTION Do not switch off the tracker during the firmware...

Page 44: ...pdate The remaining settings after the update should be checked and if necessary reinstalled Depending on the status of the GSM network the upgrade process takes an average of 2 to 10 minutes If there...

Page 45: ...ng Marking is placed on the tracker housing The tracker is packed in an individual box which protect them during transportation and storage Multipack is possible 13 Disposal Device recycling is perfor...

Page 46: ...ue 0 Sign of tracker restart 1 1 Number of active SIM card 0 SIM0 1 SIM1 2 2 No connection with server 4 3 8 4 Sign of low voltage of the battery 16 5 Sign of invalidity of coordinates validity 32 6 C...

Page 47: ...pwr_ext External power voltage value mV pwr_int Voltage in built in battery adc1 Analogue input voltage value A_IN0 adc2 Analogue input voltage value A_IN0 adc3 GSM signal level adc4 adc5 adc6 fuel1...

Page 48: ...power supply of the tracker is switched off in17 in18 Suspicion of GNSS jamming in19 GNSS is revealed in20 in21 in22 in23 Time is synchronized according to GSM in24 Can1 Can25 Fields are used to tran...

Reviews: