background image

 

GPS/GLONASS TRACKING EQUIPMENT  

 

 

 

SMART S-2422 

Operations manual 

Installation and connection of the device 

 

v1.0 

 

 

 

 

 

 

 

 

 

MOSCOW 

2020

 

 

Summary of Contents for SMART S-2422

Page 1: ...GPS GLONASS TRACKING EQUIPMENT SMART S 2422 Operations manual Installation and connection of the device v1 0 MOSCOW 2020 ...

Page 2: ...nterested in constantly improvement of the manufactured products quality Please contact our technical support by email address support navtelecom ru should you have any questions or problems with the device It is possible to download software documentation and get detailed information on the manufacturer s website https navtelecom ru en We thank you for purchasing of our product We are sure that i...

Page 3: ...face connector 11 2 DEVICE CONNECTION 12 2 1 Installation 12 2 2 SIM card installation and operation 13 2 3 Power connection 13 2 4 Universal inputs connection 14 2 4 1 Analog sensors connection 14 2 4 2 Discrete sensors connection 14 2 4 3 Pulse frequency sensors connection 15 2 5 Built in accelerometer 16 2 6 Control outputs connection 16 2 7 1 Wire informational interface IButton connection 19 ...

Page 4: ...ety by comprehensive measures improving driver and passenger s safety 1 3 Operational principles The device during its operation continuously monitors the status of the connected sensors vehicle battery voltage GSM modem signal level operational capability of navigational sensor GPS GLONASS etc At power up or USB connection to a computer the device automatically turns on At power off or USB discon...

Page 5: ... 5 47 Current consumption at 12 V voltage in operation mode on Average2 mA 80 Current consumption at 12 V voltage with turned off GLONASS and GSM modules is no more than mA 20 Maximum current consumption at 12 V voltage in the operation with the charge of the battery is not more than mA 200 Protection against polarity reversal yes Protection against prolonged overvoltage up to 500 V yes Battery3 n...

Page 6: ...ng voltage is exceeded the power protection is activated The device continues to work but is powered by the battery 2 If GPRS operates in poor communications peak consumption 10 ms consumption of the device can accede 500 mA 3 Attention Lithium polymer battery Li Po is used in the device The following rules must be observed during its operation not to heat keep away from sources of heat not to thr...

Page 7: ...MiniUSB connector for connection with a computer SIM card holder slot with ejector yellow button In the upper part of the device unit Figure 3 there are three indicators system indicator SYS modem operation indicator GSM navigation receiver indicator NAV Figure 1 Device unit front view 14 pin connector of Microfit 14 Figure 2 Device unit side view MiniUSB connector and SIM card slot with ejector F...

Page 8: ...nterface cable with MiniUSB connector 1 5 Passport 1 6 Package 1 Figure 4 14 pin connector of Microfit 14 Figure 5 Interface cable with MiniUSB connector Some cases may require connection of additional equipment not included in the standard equipment set for example fuse and fuse holder fuel level sensor external LED temperature sensor TouchMemory contact key reader Figure 6 Fuse and fuse holder ...

Page 9: ... External LED Figure 9 Temperature sensor Figure 10 TouchMemory contact key reader The manufacturer reserves the right to complete the devices with equipment whose set appearance and characteristics differ from those shown in the figures ...

Page 10: ...res 11 14 1 front cover 2 fixing hole 3 system LED indicator 4 GSM LED indicator 5 GLONASS GPS LED indicator 6 14 pin connector 7 MiniUSB connector 8 SIM card 1 ejector holder 9 SIM card holder 1 external 10 back cover 11 fixing screw of the back cover 4 pcs Figure 11 Figure 12 ...

Page 11: ...Figure 13 Figure 14 ...

Page 12: ...voltage from 0 V to 31 V FLS impulse fuel consumption sensors DRL buttons or switches Attention It is prohibited to apply a voltage more than 50 V to the device universal inputs because it may lead to the failure of the device Outputs OUT1 and OUT2 open collector type are designed to control low current loads up to 500 mA When activated a negative signal Ground is formed on these lines Connection ...

Page 13: ...han 60 C for example near heating systems etc It is also prohibited to place the device in a sealed container without heat dissipation It is prohibited to install tracker in places with high humidity and in places where there is a risk of possible ingress of liquid or large amount of dust into the case Figure 16 Device unit Location of GLONASS GPS antenna When the device is connected to the Microf...

Page 14: ...echnical characteristics When voltage surges which is more than the specified ratings occur the built in overvoltage protection system will operate in the device It is strongly recommended to connect the device to the power supply through a 1 A fuse not included in standard equipment set During installation the power supply should be connected the last turn when all the other equipment is already ...

Page 15: ...asurement event become available CPU_adc R1 R2 UIN C1 U Figure 19 Connection of analog sensors 2 4 2 Discrete sensors connection The device allows to connect any type of sensors that have two steady states on activated and off normal The voltage thresholds at which the device fixes the sensor on activating or off switching to normal depend on the line profile setting and the set levels on the volt...

Page 16: ... algorithms for example when they are averaged at parking lots energy saving when calculating engine hours and in some other device algorithms Any input which configured for operation with a discrete sensor can be used as an ignition 14 7 13 6 12 5 11 4 10 3 9 8 2 1 Fuse 1А U Ignition switch UIN1 Alarm button GND GND Car battery Figure 24 Connection of the ignition lock and alarm button Digital in...

Page 17: ... on its settings In addition to virtual sensors accelerometer is used for such functions as EcoDriving For proper operation of these functions the accelerometer must be calibrated after installing the device on the vehicle 2 6 Control outputs connection OUT1 and OUT2 open collector outputs are designed to control low current loads up to 500 mA When the output is activated turned on it connects the...

Page 18: ...te If the power source is vehicle s on board network the LED must be connected through current limiting resistor Such resistor is already installed inside the lamp in the automotive LED lamps It is only necessary to select the LED lamp under the desired voltage of the on board vehicle network 14 7 13 6 12 5 11 4 10 3 9 8 2 1 Fuse 1А GND Car battery 1 2 kOhm LED Figure 28 Connection diagram of LED ...

Page 19: ...r contacts are always marked as 30 87 and 87a The 30th pin is always in the relay Without applying voltage to the winding contacts it is permanently closed to contact 87a If a signal is applied to the winding then the 30th contact is disconnected from 87a and connected to 87 87a or 87 contacts may be absent then the relay will only work to turn on or off closing opening the power circuit 30 85 86 ...

Page 20: ...at the manufacturing plant by which the device identifies this sensor Saving the key codes in the device s memory allows to use identification when changing the security mode activating the output with the profile set TM registered key indicator and TM key indicator and also necessary for operation of the Immobilizer function The maximum number of stored keys 16 It is also allowed to connect exter...

Page 21: ...nd of the bus that is opposite to the connected device it should be closed by the last plug in sensor 14 7 13 6 12 5 11 4 10 3 9 8 2 1 Fuse 1A GND Car battery Temperature sensors DS1820 Data Data Data Data Contact pad Touch Memory DS1990A Figure 37 Connection diagram of digital temperature sensors and TouchMemory contact pad For networks sensors construction it is necessary to choose a twisted pai...

Page 22: ... should be connected to the RS 485 line of the sensor usually designated as B The RS 485 interface specifications practically do not limit the length of cables on a land vehicle 100m or more since the interface is a differential bus and is well protected from the influence of external interference 14 7 13 6 12 5 11 4 10 3 9 8 2 1 Car battery Fuse 1А GND FLS Line A RS485 Line B FLS Line A RS485 Lin...

Page 23: ...econd off There is a registration in the cellular network of the operator Weak signal 2 short flashes 1 second off There is a registration in the cellular network of the operator Medium quality signal 3 short flashes 1 second off There is a registration in the cellular network of the operator High quality signal Permanent short flashes Open GPRS session Attempts to establish communication with the...