48
adding dozens of pictures, you can slightly lower the [Qualified Reference Value] in this
interface to achieve the effect of false alarm debugging.
The calculation method is [Color Extraction]: first click [Component Properties]-[Color
Extraction] as shown in the following figure:
First, check [Image to be Inspected] to switch to the image to be inspected, and then see if the tin
color is completely extracted. On the right side of the figure, the specified color will be displayed
at the extracted position. If it is not completely extracted, it can be debugged by debugging [Hue],
[Brightness] and [Saturation] (note: the color of the empty pad cannot be extracted). If all colors
of tin are extracted, the lower limit of [Qualified Value] can only be lowered according to
[Inspected Value] to adjust the false alarm. After adjustment, click [Apply to Current
Components]-[Exit] and then return to the previous interface and click [Close].
The calculation method is [Short Circuit Inspection]: first click [Component Properties]-[Short
Circuit Setting] as shown in the following figure: