Features and Specifications Manual
P10 – 471
Doc.
No. 8201 -
Release 1.0
July 2003
Programming from
Multiline Terminal
P-10
FEATURE
DESCRIPTION
System Programming can be performed from designated Multiline
Terminals (with an LCD) connected to the first two ESI(8)-U( ) ETU ports.
Some programming changes can be entered while the system is operating,
other programming changes occur when the affected telephones and
circuits are idle.
SYSTEM
AVAILABILITY
Terminal Type
Multiline Terminals (with LCD).
Required Components
ESIB(8)-U( ) or ESIE(8)-U( )ETU
OPERATING
PROCEDURES
SERVICE
CONDITIONS
The first two Multiline Terminal ports are programming positions
(default: Stations 100 and 101).
Both stations can go off-line at the same time to program the system.
When PC Programming is being used with the system, programming
from a Multiline Terminal cannot be performed. When programming
from a Multiline Terminal is being performed, PC Programming cannot
be performed.
GUIDE TO
FEATURE
PROGRAMMING
Refer to the Xen IPK System Programming Manual for additional
information.
Order
and
Shortcut
System Data Name
Memory
Block
Function
1-8-07
Attendant
Page-Line
Key
1-8-08
Station
Page-Line
Key
¶
+BS
Card Interface Slot Assignment
7-1
¶
+BS
Telephone Type Assignment
7-2