130
CHAPTER 10 A/D CONVERTER
Conversion Start
CS=1, TRG=0
A /D Conversion
ADCR
INTAD
ANIn
ANIn
ANIm
ANIn
ANIm
ANIm
ANIn
ANIn
ADM Rewrite
CS=1, TRG=0
ADM Rewrite
CS=0, TRG=0
Conversion suspended
Conversion results are
not stored
Stop
(2) A/D conversion operation in software start
When bit 6 (TRG) and bit 7 (CS) of A/D converter mode register (ADM) are set to 0 and 1, respectively, the
A/D conversion starts on the voltage applied to the analog input pins specified with bits 1 to 3 (ADM1 to
ADM3) of ADM.
Upon termination of the A/D conversion, the conversion result is stored in the A/D conversion result register
(ADCR) and the interrupt request signal (INTAD) is generated. After one A/D conversion operation is started
and terminated, the next A/D conversion operation starts immediately. The A/D conversion operation con-
tinues repeatedly until new data is written to ADM.
If data with CS set to 1 is written to ADM again during A/D conversion, the converter suspends its A/D
conversion operation and starts A/D conversion on the newly written data.
If data with CS set to 0 is written to ADM during A/D conversion, the A/D conversion operation stops im-
mediately.
Figure 10-8. A/D Conversion by Software Start
Remarks 1. n = 0, 1, ... , 7
2. m = 0, 1, ... , 7
Summary of Contents for NEC PD78081(A)
Page 23: ...xii MEMO...
Page 37: ...14 CHAPTER 1 OUTLINE MEMO...
Page 47: ...24 CHAPTER 2 PIN FUNCTION MEMO...
Page 91: ...68 CHAPTER 4 PORT FUNCTIONS MEMO...
Page 125: ...102 CHAPTER 6 8 BIT TIMER EVENT COUNTERS 5 AND 6 MEMO...
Page 157: ...134 CHAPTER 10 A D CONVERTER MEMO...
Page 193: ...170 CHAPTER 11 SERIAL INTERFACE CHANNEL 2 MEMO...
Page 253: ...230 CHAPTER 16 INSTRUCTION SET MEMO...