ND-45492 (E)
CHAPTER 3
Page 73
Revision 2.0
NAP 200-005
Sheet 2/7
Connection of Battery
CAUTION
Battery Replacement Table and Battery Warnings
The label which shows battery replacement table and battery warnings is attached to the reverse side of Front
Cover for PIM and BATTM.
During the battery installation process, the warning statements must be observed. When replacing batteries, the
battery replacement table should be observed to increase battery life and ensure a safe operation.
•
ELECTROLYTE LEAKAGE OR OTHER HAZARDS MAY RE-
SULT IF THE BATTERY IS NOT REPLACED IN ACCOR-
DANCE WITH THE SPECIFIED INTERVALS.
AMBIENT
TEMPERATURE
25°C
(77°F)
25°C ~ 30°C
(77°F ~ 86°F)
30°C ~ 40°C
(86°F ~ 104°F)
REPLACEMENT
INTERVAL
2.5 ~ 3
YEARS
2.0 ~ 2.5
YEARS
1.5 ~ 2.0
YEARS
FRONT COVER
PIM/BATTM
LABEL
TO PREVENT INJURY AND SKIN BURN, PAY
ATTENTION TO THE FOLLOWING.
•
DO NOT STRIKE A MATCH OR CAUSE A SPARK IN VI-
CINITY OF BATTERY.
•
PLACE THE EQUIPMENT IN A WELL VENTILATED AR-
EA.
•
DO NOT SHORT.
•
REPLACE BATTERY ONLY AFTER BATTERY GASES
HAVE BEEN DISPERSED.
CAUTION
BATTERY REPLACEMENT TABLE
INSTALLATION DATE:
,
.