ND-45492 (E)
CHAPTER 3
Page 57
Revision 2.0
(6) Do the following cable connectons in the same manner as for Floor Standing Installation.
(a) Connect the AC CORD-B cables to the terminals inside the BASE (Refer to
Figure 003-11
through
Figure 003-13
).
(b) Connect the PZ-PW86 cards to each other using PWR CA-A cables (Refer to
Figure 003-14
through
Figure 003-15
).
(c) Mount the PN-BS00 card in the BUS slot of PIM0, and mount the PN-BS01 card in each BUS slot of
PIM1 through PIM3 (Refer to
Figure 003-16
).
Then, connect all the BUS cards (PN-BS00/PN-BS01) to each other using BUS cables (
Figure 003-
17
and
Figure 003-18
).
NAP 200-003
Sheet 35/37
Installation of Main Equipment