(11) External Tone Source Equipment
The cross connection for a customer owned external tone source equipment is shown in
Figure 007-32
through
Figure 007-34
as an example.
Requirement for the External Tone Source Equipment
•
Output level
: Less than 0 dBm (Adjustable)
•
Output impedance
: Less than 1 k
Ω
(When using PN-4COT and PN-DK00)
: Less than 10 k
Ω
(When using Pin Jacks on PN-TNTA)
•
Control Method
: Start - Ground Start
Note 1
: Stop - Ground Off (Open)
Note 1:
The current capacity of relay driver (PN-DK00 card) is 0.125 A.
Note 2:
When connecting the external tone source equipment using the PN-4COT and PN-DK00 cards, an appro-
priate diode must be installed on the MDF, as shown in
Figure 007-32
.
NAP 200-007
Sheet 39/56
Termination of Cables on the MDF