CHAPTER 3
ND-45492 (E)
Page 98
Revision 2.0
* Major and minor alarm connections for external indications are located on LTC0 of PIM0, only.
NAP 200-007
Sheet 13/56
Termination of Cables on the MDF
Table 007-3 LTC0-LTC2 MDF Cross Connection Information (2 of 4)
PIN
RUNNING
CABLE
STATION
CABLE
SLOTS
TYPE OF INTERFACE
COT
(4COT)
COT
(2COT)
2-WIRE
E&M TIE
LINE
(2ODT)
4-WIRE
E&M TIE
LINE
(2ODT)
DID
(AUC)
SLT
(4LC)
SLT
(AUC)
38
BK-GN
GN
4
T0
T0
T0
TxT0
T0
T0
T0
13
GN-BK
RD
R0
R0
R0
TxR0
R0
R0
R0
39
BK-BR
BK
T1
T1
T1
RcvT0
T1
T1
T1
14
BR-BK
YL
R1
R1
R1
RcvR0
R1
R1
R1
40
BK-SL
GN
T2
T2
TxT1
T2
15
SL-BK
RD
R2
R2
TxR1
R2
41
YL-BL
BK
T3
T3
RcvT1
T3
16
BL-YL
YL
R3
R3
RcvR1
R3
42
YL-OR
GN
5
T0
T0
T0
TxT0
T0
T0
T0
17
OR-YL
RD
R0
R0
R0
TxR0
R0
R0
R0
43
YL-GN
BK
T1
T1
T1
RcvT0
T1
T1
T1
18
GN-YL
YL
R1
R1
R1
RcvR0
R1
R1
R1
44
YL-BR
GN
T2
T2
TxT1
T2
19
BR-YL
RD
R2
R2
TxR1
R2
45
YL-SL
BK
T3
T3
RcvT1
T3
20
SL-YL
YL
R3
R3
RcvR1
R3
46
VI-BL
GN
6
T0
T0
T0
TxT0
T0
T0
T0
21
BL-VI
RD
R0
R0
R0
TxR0
R0
R0
R0
47
VI-OR
BK
T1
T1
T1
RcvT0
T1
T1
T1
22
OR-VI
YL
R1
R1
R1
RcvR0
R1
R1
R1
48
VI-GN
GN
T2
T2
TxT1
T2
23
GN-VI
RD
R2
R2
TxR1
R2
49
VI-BR
BK
T3
T3
RcvT1
T3
24
BR-VI
YL
R3
R3
RcvR1
R3
50
VI-SL
MN *
25
SL-VI
MJ *