Troubleshooting 8-25
The PXE boot (network boot) fails or the server is not found on the network:
T
Is the cable connected properly?
→
Connect the proper cable to the network port on the rear of the Express server. In
addition, make sure that the used cable conforms to the network interface standard.
T
Is BIOS configuration correct?
→
The internal LAN controller may be disabled with the BIOS SETUP utility of the
server. Check the setting with the BIOS setup utility.
T
Have the protocol and service already configured?
→
Install the distinctive network driver for the server. Make sure that the protocol,
such as TCP/IP, and services are properly specified.
T
Is the transfer speed correct?
→
Open the network property dialog box in control panel to specify the link speed
and duplex value the same as the value specified for HUB.
The Telnet Service is not installed.
→
Adjust the computer name to 14 characters or less, and then install the Telnet Service
according to <How to install the Telnet Service>.
<How to install the Telnet Service>
1.
Click [Run] on Start menu.
2.
Type "tlntsvr /service" in the [Open] box, and click [OK].
3.
Click Start menu, point to [Control Panel] and click [Computer Management] and then
click the [Services] to specify whether the Telnet Service is registered.
* When the installation of Telnet Service is finished, there is no problem if the computer
name is set to 15 characters or more.
Power ON/OFF (Wake On LAN) feature does not work:
→
Immediately after the AC power is turned on, the Remote Power ON/OFF feature
(Wake ON LAN) is disabled. Start Windows 2003 once, provide settings as shown
below, then shutdown the system. After restart, the Remote Power On/Off feature
is available unless the AC power is turned off.
Select [Start]
→
[Administrative Tools]
→
[Computer Management].
Select Device Manager, double-click [Intel(R) PRO/1000EB Network Connection
with I/O Acceleration #n] under Network Adapter, and specify as follows in
[Detail] tab.
PME:
[ON]
Wake On:
[Magic Packet]
Summary of Contents for N8100-1429F
Page 16: ...x This page is intentionally left blank...
Page 34: ...1 18 Notes on Using Your Server This page is intentionally left blank...
Page 172: ...5 36 Installing the Operating System with Express Setup This page is intentionally left blank...
Page 194: ...6 22 Installing and Using Utilities This page is intentionally left blank...
Page 206: ...7 12 Maintenance This page is intentionally left blank...
Page 284: ...9 36 Upgrading Your Server This page is intentionally left blank...
Page 286: ...A 2 Specifications This page is intentionally left blank...
Page 294: ...C 2 IRQ This page is intentionally left blank...
Page 348: ...F 2 Using a Client Computer Which Has a CD Drive This page is intentionally left blank...
Page 352: ...G 4 Product Configuration Record Table This page is intentionally left blank...