![NEC N8100-1429F User Manual Download Page 129](http://html1.mh-extra.com/html/nec/n8100-1429f/n8100-1429f_user-manual_4242032129.webp)
Configuring Your Server 4-45
Check Consistency
Run LSI Software RAID Configuration Utility
Perform Check Consistency
Exit LSI Software RAID Configuration Utility
1.
Run LSI Software RAID Configuration Utility.
2.
Select "Check Consistency" from the TOP menu.
The "Virtual Drives" screen appears.
3.
Move the cursor onto the virtual drive to be checked, and press
Space
to select it.
4.
When virtual drive has been selected, press
F10
to start consistency check.
5.
A confirmation screen for execution appears. Select "Yes".
The consistency check starts.
When the progress bar in the "Check Consistency Progress" screen indicates 100%, the
consistency check is completed.
6.
Press
Esc
to return to the TOP menu and exit LSI Software RAID Configuration Utility.
IMPORTANT:
Be sure to execute Check Consistency after creating
configuration.
Summary of Contents for N8100-1429F
Page 16: ...x This page is intentionally left blank...
Page 34: ...1 18 Notes on Using Your Server This page is intentionally left blank...
Page 172: ...5 36 Installing the Operating System with Express Setup This page is intentionally left blank...
Page 194: ...6 22 Installing and Using Utilities This page is intentionally left blank...
Page 206: ...7 12 Maintenance This page is intentionally left blank...
Page 284: ...9 36 Upgrading Your Server This page is intentionally left blank...
Page 286: ...A 2 Specifications This page is intentionally left blank...
Page 294: ...C 2 IRQ This page is intentionally left blank...
Page 348: ...F 2 Using a Client Computer Which Has a CD Drive This page is intentionally left blank...
Page 352: ...G 4 Product Configuration Record Table This page is intentionally left blank...