8-10 Troubleshooting
Error
code
Error message
Recommended Action
0B71
System Temperature out of the range.
Contact your service representative to
replace the fan.
0B74
The error occurred during voltage sensor
reading.
0B75
System voltage out of the range.
Contact your service representative.
0B80
BMC Memory Test Failed.
0B81
BMC Firmware Code Area CRC check failed.
0B82
BMC Core Hardware failure.
0B83
BMC IBF or OBF check failed.
Turn off the power once and then on again
to start the server. If the error cannot be
corrected, contact your service
representative.
0B8A
BMC SEL area full.
Start the SETUP and select [Server] -
[Event Log configuration] - [Clear All Error
Logs] and press
Enter
to clear event logs.
0B8B
BMC progress check timeout.
0B8C
BMC command access failed.
0B8D
Could not redirect the console - BMC Busy -
0B8E
Could not redirect the console - BMC Error -
Turn off the power once and then on again
to start the server. If the error cannot be
corrected, contact your service
representative.
0B8F
Could not redirect the console - BMC
Parameter Error -
0B90
BMC Platform Information Area corrupted.
0B91
BMC update firmware corrupted.
Turn off the power once and then on again
to start the server. If the error cannot be
corrected, contact your service
representative.
0B92
Internal Use Area of BMC FRU corrupted.
This is not a fatal error. Turn off the power
once and then on again to restart the
server. If the error cannot be corrected,
contact your service representative.
0B93
BMC SDR Repository empty.
Turn off the power once and then on again
to restart the server. If the error cannot be
corrected, contact your service
representative.
0B94
IPMB signal lines do not respond.
This is not a fatal error. Turn off the power
once and then on again to restart the
server. If the error cannot be corrected,
contact your service representative.
0B95
BMC FRU device failure.
This is not a fatal error. Turn off the power
once and then on again to restart the
server. If the error cannot be corrected,
contact your service representative.
0B96
BMC SDR Repository failure.
0B97
BMC SEL device failure.
0B98
BMC RAM test error.
0B99
BMC Fatal hardware error.
Turn off the power once and then on again
to start the server. If the error cannot be
corrected, contact your service
representative.
0B9A
BMC not responding.
Update the RMC firmware. If the error
cannot be corrected, contact your service
representative.
Summary of Contents for N8100-1429F
Page 16: ...x This page is intentionally left blank...
Page 34: ...1 18 Notes on Using Your Server This page is intentionally left blank...
Page 172: ...5 36 Installing the Operating System with Express Setup This page is intentionally left blank...
Page 194: ...6 22 Installing and Using Utilities This page is intentionally left blank...
Page 206: ...7 12 Maintenance This page is intentionally left blank...
Page 284: ...9 36 Upgrading Your Server This page is intentionally left blank...
Page 286: ...A 2 Specifications This page is intentionally left blank...
Page 294: ...C 2 IRQ This page is intentionally left blank...
Page 348: ...F 2 Using a Client Computer Which Has a CD Drive This page is intentionally left blank...
Page 352: ...G 4 Product Configuration Record Table This page is intentionally left blank...