![NEC N8100-1429F User Manual Download Page 132](http://html1.mh-extra.com/html/nec/n8100-1429f/n8100-1429f_user-manual_4242032132.webp)
4-48 Configuring Your Server
Disk Array
LSI Software RAID Configuration Utility manages Disk Array by a number beginning with 0. You
can see a number of Disk Array where [Axx] of [Objects - PHYSICAL DRIVE SELECTION
MENU] DG X] in [Objects] menu.
Universal RAID Utility manages Disk Array by a number beginning with 1. You can see a number
of Disk Array where [Disk Array] in the property of Logical Drive on RAID Viewer or [RAID
Controller #X Disk Array #Y] in the property of Disk Array on raidcmd.
Physical Drive and Physical Device
LSI Software RAID Configuration Utility manages Physical Drive by ID. You can see ID of
Physical Drive where [Port #] of [Objects - PHYSICAL DRIVE SELECTION MENU] DG X] in
[Objects] menu.
Universal RAID Utility manages Physical Device by a number beginning with 1 and ID. The ID is
same value of ID on LSI Software RAID Configuration Utility. You can see a number and ID of
Physical Device where [Number] and [ID] in the property of Physical Device on RAID Viewer or
[RAID Controller #X Physical Device #Y] and [ID] in the property of Physical Device on raidcmd.
Setting of Priority
LSI Software RAID Configuration Utility displays and sets Rebuild Priority and Consistency Check
Priority of RAID Controller by percentage. But, Universal RAID Utility uses three levels as
High/Middle/Low for them.
The setting value of LSI Software RAID Configuration Utility and the display level of Universal
RAID Utility
Item
Setting value of LSI Software
RAID Configuration Utility
Universal RAID Utility Level
15 to 100
High
8 to 14
Middle
Rebuild Priority
Rebuild Rate (LSI Software
RAID Configuration Utility)
0 to 7
Low
15 to 100
High
8 to 14
Middle
Consistency Check Priority
Chk Const Rate (LSI Software
RAID Configuration Utility)
0 to 7
Low
Summary of Contents for N8100-1429F
Page 16: ...x This page is intentionally left blank...
Page 34: ...1 18 Notes on Using Your Server This page is intentionally left blank...
Page 172: ...5 36 Installing the Operating System with Express Setup This page is intentionally left blank...
Page 194: ...6 22 Installing and Using Utilities This page is intentionally left blank...
Page 206: ...7 12 Maintenance This page is intentionally left blank...
Page 284: ...9 36 Upgrading Your Server This page is intentionally left blank...
Page 286: ...A 2 Specifications This page is intentionally left blank...
Page 294: ...C 2 IRQ This page is intentionally left blank...
Page 348: ...F 2 Using a Client Computer Which Has a CD Drive This page is intentionally left blank...
Page 352: ...G 4 Product Configuration Record Table This page is intentionally left blank...