8-40 Troubleshooting
When STATUS lamp is flashing in amber
On-screen message
Description
Recommended action
HDD Fault
An error was detected in hard disk drive.
1. Check installation status of the failed hard disk drive.
2. While hard disk drives are in RAID configuration (RAID1, RAID5,
RAID6, RAID10, or RAID50), a single failed hard disk drive does not
affect the operation of the server. However, it is recommended to
replace the failed hard disk drive and rebuild the hard disk drives as
soon as possible.
3. If the same error persists, contact your service representative.
FAN1 Alarm
A warning occurred in FAN #1.
FAN2 Alarm
A warning occurred in FAN #2.
FAN3 Alarm
A warning occurred in FAN #3.
FAN4 Alarm
A warning occurred in FAN #4.
FAN5 Alarm
A warning occurred in FAN #5.
FAN6 Alarm
A warning occurred in FAN #6.
FAN7 Alarm
A warning occurred in FAN #7.
FAN8 Alarm
A warning occurred in FAN #8.
Check installation status of the failed fan.
If the same error persists, contact your service representative.
BB +1.0V Alm 07
+1.0V voltage warning (upper limit) occurred.
BB +1.0V Alm 00
+1.0V voltage warning (lower limit) occurred.
BB +1.5V Alm 07
+1.5V voltage warning (upper limit) occurred.
BB +1.5V Alm 00
+1.5V voltage warning (lower limit) occurred.
BB +3.3V Alm 07
+3.3V voltage warning (upper limit) occurred.
BB +3.3V Alm 00
+3.3V voltage warning (lower limit) occurred.
BB +5V Alm 07
+5V voltage warning (upper limit) occurred.
BB +5V Alm 00
+5V voltage warning (lower limit) occurred.
BB +12V Alm 07
+12V voltage warning (upper limit) occurred.
BB +12V Alm 00
+12V voltage warning (lower limit) occurred.
BB FSB_VTT Alm 07
FSB VTT voltage warning (upper limit) occurred.
BB FSB_VTT Alm 00
FSB VTT voltage warning (lower limit) occurred.
BB +1.5V ESB Alm 07
+1.5V ESB voltage warning (upper limit) occurred.
BB +1.5V ESB Alm 00
+1.5V ESB voltage warning (lower limit) occurred.
BB +3.3V AUX Alm 07
+3.3V AUX voltage warning (upper limit) occurred.
BB +3.3V AUX Alm 00
+3.3V AUX voltage warning (lower limit) occurred.
BB +3.3Vs Alm 07
+3.3Vs voltage warning (upper limit) occurred.
BB +3.3Vs Alm 00
+3.3Vs voltage warning (lower limit) occurred.
1. Reboot (reset) the server.
2. Turn off the DC power of the server, and disconnect the AC power
cord. Then, connect the AC power cord again, and reboot the server.
If the same error persists, contact your service representative.
Summary of Contents for Express5800/140Rf-4
Page 7: ......
Page 8: ......
Page 9: ......
Page 20: ...x This page is intentionally left blank ...
Page 186: ...4 88 Configuring Your Server 3 Setting menu for VD 0 is displayed ...
Page 194: ...4 96 Configuring Your Server This page is intentionally left blank ...
Page 226: ...5 32 Installing the Operating System with Express Setup This page is intentionally left blank ...
Page 264: ...7 18 Maintenance This page is intentionally left blank ...
Page 413: ...C 4 This page is intentionally left blank ...
Page 457: ...E 22 Installing Windows Server 2003 This page is intentionally left blank ...