4-26 Configuring Your Server
Option Parameter
Description Your
Setting
Boot
Monitoring
[Disabled]
5 minutes
10 minutes
15 minutes
20 minutes
25 minutes
30 minutes
35 minutes
40 minutes
45 minutes
50 minutes
55 minutes
60 minutes
Indicates whether the boot monitoring
function is enabled or disabled on booting.
To use this function, install NEC ESMPRO
Agent. Do not use this function if the system
is booted from OS without installation of NEC
ESMPRO Agent or CD-ROM. Set this item to
"Disabled" if ARCServe uses the Disaster
Recovery Option.
Boot
Monitoring
Policy
[Retry 3 Times]
Always Retest
Appears when the boot monitoring feature is
enabled. This item indicates the processing
at the occurrence of timeout during boot
monitoring.
If [Retry 3 times] is selected, the system is
reset after the occurrence of timeout and OS
boot is retried up to three times.
If [Always Reset] is selected, the system is
reset after the occurrence of timeout and OS
boot is retried repeatedly.
Thermal
Sensor
Disabled
[Enabled]
Indicates whether the temperature sensor
monitoring function is enabled or disabled.
BMC IRQ
Disabled
[IRQ 11]
Indicates the IRQ of the BMC interrupt.
Post Error
Pause
Disabled
[Enabled]
Indicates whether POST is aborted once at
the end of POST if an error occurs during the
execution of POST.
AC-LINK Stay
Off
[Last State]
Power On
Indicates the AC-LINK function. Shows the
state of the power of the server.
Power ON
Delay Time
[20] - 255
Sets the power on delay time when "Power
On" or "Last State" is specified for AC LINK.
Platform
Event
Filtering
Disabled
[Enabled]
Enables or disables the Platform Event
Filtering feature of the baseboard
management controller (BMC).
[ ]: Factory-set
The table below shows the operation when the AC power to the server is turn off once and then on
again, depending on the setting of "AC-LINK."
System status before AC power off
Setting of AC-LINK
Stay Off
Last State
Power On
Operating Off
On
On
Aborting (DC power being off also)
Off
Off
On
Forced shutdown
Off
Off
On
* Press the POWER/SLEEP switch continuously at least four seconds. This forcibly turns off the
power.
IMPORTANT:
Set this item to "Power on" in order to link the AC
power source supplied from UPS when the server is connected to UPS.
Summary of Contents for Express5800/140Rf-4
Page 7: ......
Page 8: ......
Page 9: ......
Page 20: ...x This page is intentionally left blank ...
Page 186: ...4 88 Configuring Your Server 3 Setting menu for VD 0 is displayed ...
Page 194: ...4 96 Configuring Your Server This page is intentionally left blank ...
Page 226: ...5 32 Installing the Operating System with Express Setup This page is intentionally left blank ...
Page 264: ...7 18 Maintenance This page is intentionally left blank ...
Page 413: ...C 4 This page is intentionally left blank ...
Page 457: ...E 22 Installing Windows Server 2003 This page is intentionally left blank ...