Troubleshooting 8-21
Error
code
Error message
Recommended Action
82A0
Unsupported DIMM detected in DIMM #1
DIMM numbers shown in error message are
as show below.
DIMM #1 to DIMM #8:
DIMM #1 to DIMM #8 on memory board A
DIMM #9 to DIMM #16:
DIMM #1 to DIMM #8 on memory board B
DIMM #17 to DIMM #24:
DIMM #1 to DIMM #8 on memory board C
DIMM #25 to DIMM #32:
DIMM #1 to DIMM #8 on memory board D
1. Take one of the following measures to
reboot (reset) the server.
* Issue an OS command.
* Press Ctrl + Alt + Del.
* Press the RESET switch.
* Issue a command from Web browser of
EXPRESSSCOPE Engine 2 or NEC
DianaScope Manager.
2. Replace the DIMM that has been replaced
or additionally installed.
3. Replace the failed DIMM.
4. Replace the relevant memory board.
5. If the same error persists, contact your
service representative.
82A1
Unsupported DIMM detected in DIMM #2
82A2
Unsupported DIMM detected in DIMM #3
82A3
Unsupported DIMM detected in DIMM #4
82A4
Unsupported DIMM detected in DIMM #5
82A5
Unsupported DIMM detected in DIMM #6
82A6
Unsupported DIMM detected in DIMM #7
82A7
Unsupported DIMM detected in DIMM #8
82A8
Unsupported DIMM detected in DIMM #9
82A9
Unsupported DIMM detected in DIMM #10
82AA
Unsupported DIMM detected in DIMM #11
82AB
Unsupported DIMM detected in DIMM #12
82AC
Unsupported DIMM detected in DIMM #13
82AD
Unsupported DIMM detected in DIMM #14
82AE
Unsupported DIMM detected in DIMM #15
82AF
Unsupported DIMM detected in DIMM #16
82B0
Unsupported DIMM detected in DIMM #17
82B1
Unsupported DIMM detected in DIMM #18
82B2
Unsupported DIMM detected in DIMM #19
82B3
Unsupported DIMM detected in DIMM #20
82B4
Unsupported DIMM detected in DIMM #21
82B5
Unsupported DIMM detected in DIMM #22
82B6
Unsupported DIMM detected in DIMM #23
82B7
Unsupported DIMM detected in DIMM #24
82B8
Unsupported DIMM detected in DIMM #25
82B9
Unsupported DIMM detected in DIMM #26
82BA
Unsupported DIMM detected in DIMM #27
82BB
Unsupported DIMM detected in DIMM #28
82BC
Unsupported DIMM detected in DIMM #29
82BD
Unsupported DIMM detected in DIMM #30
82BE
Unsupported DIMM detected in DIMM #31
82BF
Unsupported DIMM detected in DIMM #32
Summary of Contents for Express5800/140Rf-4
Page 7: ......
Page 8: ......
Page 9: ......
Page 20: ...x This page is intentionally left blank ...
Page 186: ...4 88 Configuring Your Server 3 Setting menu for VD 0 is displayed ...
Page 194: ...4 96 Configuring Your Server This page is intentionally left blank ...
Page 226: ...5 32 Installing the Operating System with Express Setup This page is intentionally left blank ...
Page 264: ...7 18 Maintenance This page is intentionally left blank ...
Page 413: ...C 4 This page is intentionally left blank ...
Page 457: ...E 22 Installing Windows Server 2003 This page is intentionally left blank ...