8-46 Troubleshooting
Fail to access to the CD-R disk:
8
Is the mounting surface correct?
→
Take out the CD-R disk from the tray, and then set it again with its labeled surface
upward.
8
Is there any soil or crack on CD-R disk?
→
Make sure there is no soil due to fingerprint or others on the disk surface. Also
make sure that there is no crack on the disk surface. Clean the disk surface if it is
soiled.
If read-out still fails, set another disk of which data has been successfully read out
to check if the drive can read the disk.
8
Is the CD-R disk closed?
→
Close the session or set the disk in closed status, and try to read again.
8
Are the CD-R disk and writing software appropriate to the disk drive?
→
The DVD-ROM drive of the server may fail if the combination of disk drive,
writing software, and CD-R is not correct.
Fail to access the hard disk drive:
(Refer to the documentation supplied with the RAID Controller.)
8
Is the hard disk drive applicable to the server?
→
Operation of any device that is not authorized by NEC is not guaranteed.
8
Is the hard disk drive properly installed?
→
Make sure to lock the hard disk drive with the lever on its handle. The hard disk
drive is not connected to the internal connector when it is not completely installed
(see Chapter 9).
Fail to access the (internal or external) SCSI devices:
8
Is the SCSI device applicable to the server?
→
Operation of any SCSI device that is not authorized by NEC is not guaranteed.
8
Are SCSI devices properly configured?
→
When the server has external SCSI devices connected, device settings, including
SCSI ID and terminator, are required. Refer to the manual that comes with the
SCSI device for details.
8
Are the SCSI controllers (including optional controllers) properly configured?
→
If the server has an optional SCSI controller installed and SCSI devices connected
to it, use the BIOS setup utility that comes with the optional SCSI controller for
proper configuration. Refer to the manual that comes with the optional SCSI
controller for details.
Fail to access to internal or external devices (or such devices fail to operate):
Summary of Contents for Express5800/140Rf-4
Page 7: ......
Page 8: ......
Page 9: ......
Page 20: ...x This page is intentionally left blank ...
Page 186: ...4 88 Configuring Your Server 3 Setting menu for VD 0 is displayed ...
Page 194: ...4 96 Configuring Your Server This page is intentionally left blank ...
Page 226: ...5 32 Installing the Operating System with Express Setup This page is intentionally left blank ...
Page 264: ...7 18 Maintenance This page is intentionally left blank ...
Page 413: ...C 4 This page is intentionally left blank ...
Page 457: ...E 22 Installing Windows Server 2003 This page is intentionally left blank ...