9-12 Upgrading Your Server
5.
If using the server with the hard disk drive removed, install the dummy block in the empty
slot.
6.
Install the front bezel you removed in step 2.
When the hard disks are in the disk array configuration, you can restore the state before an error
using the auto-rebuild feature that stores the data in the old hard disk into a new one.
The auto-rebuild feature is available for the RAID1, RAID5, or RAID010 disk array configuration.
Auto-rebuild is carried out when you hot-swap a failed hard disk with a new one (replace the disk
while the server is powered). While auto-rebuild is in progress, the DISK lamp flashes green and
amber alternatively to indicate it.
IMPORTANT:
When auto-rebuild fails, the DISK lamp lights in amber. Remove
and install the hard disk again to restart auto-rebuild.
If the disk array monitoring utility is installed, it may display or act
as follows. If the DISK lamp does not light in amber after auto-
rebuild, however, auto-rebuild has completed successfully.
– Displays "Rebuild was cancelled" on the screen while auto-
rebuild is in progress.
– Appears to stop and restart auto-rebuild.
Observe the following notes for auto-rebuild.
Do not power off the server in the period between a hard disk error and completion of
auto-rebuild.
When you removed a hard disk, wait at least 90 seconds before installing the hard disk
back again.
Do not replace another hard disk while rebuilding is in progress. (The DISK lamp flashes
in green and amber alternatively while rebuilding the hard disk.)
Summary of Contents for Express5800/120Re
Page 12: ...iv This page is intentionally left blank ...
Page 34: ...1 16 Notes on Using Your Server This page is intentionally left blank ...
Page 136: ...4 38 Configuring Your Server This page is intentionally left blank ...
Page 182: ...5 46 Installing the Operating System with Express Setup This page is intentionally left blank ...
Page 206: ...6 24 Installing and Using Utilities This page is intentionally left blank ...
Page 218: ...7 12 Maintenance This page is intentionally left blank ...
Page 316: ...C 2 IRQ This page is intentionally left blank ...
Page 346: ...F 4 Product Configuration Record Table This page is intentionally left blank ...