UNIVERGE SV8100
Issue 5.0
General Description Manual
2 - 43
Auto-Answer of Non-Ringing Lines
With Auto-Answer of Non-Ringing Lines, an extension user can automatically answer
trunk calls that ring other extensions (not their own). This helps a user that has to
answer calls for co-workers that are away from their desks. When the user lifts the
handset, they automatically answer the ringing calls based on Trunk Group Routing
programming. The extension user ringing calls, however, always have priority over
calls ringing co-worker extensions.
Long Conversation Cutoff
For incoming and outgoing central office calls, each trunk can be programmed to
disconnect after a defined time. The time begins when the trunk is seized and
disconnects the call after the time expires.
When used with the Warning Tone for Long Conversation feature, the system can
provide a warning tone on outgoing trunks calls before the call is disconnected.
Maintenance
The UNIVERGE SV8100 system has several utilities to assist in troubleshooting and
diagnosing problems both during and after installation.
PCPro can remotely access the UNIVERGE SV8100 for maintenance and
diagnostics. Within PCPro, the debug terminal can be accessed to monitor the
systems activity and logging. PCPRo also has built-in reports that can display alarm
data. If need be, an option in PCPro allows the technician to reset or initialize the
system remotely. If the technician determines the problem is isolated to a specific slot,
PCPro can reset only the slot in question.
The SV8100 Maintenance manual contains a number of flow charts to help
technicians diagnose and resolve problems that may arise during and after the
installation of the UNIVERGE SV8100 system.
Meet Me Conference
With Meet Me Conference, an extension user can set up a Conference with their
current call and up to 31 other internal or external parties. Each party joins the
Conference by dialing a Meet Me Conference code. Meet Me Conference lets
extension users have a telephone meeting – without leaving the office.
The CD-CP00-US provides two blocks of 32 conference circuits, allowing each block
to have any number of internal or external parties conferenced up to the block limit of
32.
Summary of Contents for DTL-12BT-1 - DT330 - Plus BCH
Page 2: ......
Page 3: ...General Description Manual INT 2069 UNIV Issue 5 0 Version 3000...
Page 4: ......
Page 6: ......
Page 20: ...Issue 5 0 UNIVERGE SV8100 R 12 Regulatory NOTES...
Page 132: ...Issue 5 0 UNIVERGE SV8100 2 90 Features THIS PAGE INTENTIONALLY LEFT BLANK...
Page 183: ......
Page 184: ...GENERAL DESCRIPTION MANUAL NEC Unified Solutions Inc Issue 5 0 Version 3000...