Issue 5.0
UNIVERGE SV8100
5 - 22
Hardware Specifications
S
ECTION
5
P
OWER
R
EQUIREMENTS
A dedicated 100VAC/
120VAC/220VAC/230 – 240VAC
50Hz/60Hz circuit located within
seven feet of the chassis is required. A separate dedicated outlet for each chassis
should be installed.
5.1
Power Supply Specifications
AC Power Supply:
Dedicated 15 Amp circuit
Power Requirements: 120 VAC @ 15A Controlling/Base Chassis
Power Consumption: Base Chassis=263VA,
Expansion Chassis=263VA, total 1052VA
Input Voltage: 90VAC to 264VAC
(Rated Voltage: 100VAC/120VAC/220VAC - 240VAC)
Frequency:
47Hz – 63Hz (Rated frequency: 50/60Hz)
Phase and Wire: Single Phase, 2 Line + PE Type
Grounding Requirements: No. 14 AWG copper wire
Feeding Voltage:
D
term
/OPX/DID: -48V
SLT: 25mA / -28V
With input voltage of 120 VAC and with full load conditions:
Output Power: Base chassis=130W, Expansion chassis=130W, total 520W
AC Input I: Base chassis=2.19A, Expansion chassis=2.19A, total 8.76A
VA @ 120V: Base chassis=263VA, Expansion chassis=263VA,
total 1052VA
Table 5-18 Cabling Requirements
Connected Equipment
Cable
Music on Hold and Background Music Sources
Hi-Fi Shielded Audio Cable
External Amplifier
Hi-Fi Shielded Audio Cable
ITL Cabling
Cat 5 Straight Data Network
Cable – 328.1 ft (100m)
maximum distance.
Double Pole/Neutral Fusing (power supply fuses are located at
both the L and N side).
Summary of Contents for DTL-12BT-1 - DT330 - Plus BCH
Page 2: ......
Page 3: ...General Description Manual INT 2069 UNIV Issue 5 0 Version 3000...
Page 4: ......
Page 6: ......
Page 20: ...Issue 5 0 UNIVERGE SV8100 R 12 Regulatory NOTES...
Page 132: ...Issue 5 0 UNIVERGE SV8100 2 90 Features THIS PAGE INTENTIONALLY LEFT BLANK...
Page 183: ......
Page 184: ...GENERAL DESCRIPTION MANUAL NEC Unified Solutions Inc Issue 5 0 Version 3000...