16xx-Timers
162x-SLI (Analog Single Line) Timers
1621-Incoming
690
◆
System Options: 1001-1702
DSX Software Manual
162x-SLI (Analog Single Line) Timers
1621-Incoming
Description
Use this program to adjust the timers that affect incoming calls to analog single line telephones.
Options
1621-01: Minimum DP Break Timer
(Minimum Break)
Use this option to de
fi
ne the minimum amount of time the loop must be opened to properly decode the dial
pulse digits sent from analog devices connected to single line PCBs.
Change this value only if the con-
nected analog devices are set to dial at a rate other than 10 PPS.
Features
• None
IntraMail Features
• None
Options
•
5-1275
mS
Default
•
10
mS
1621-02: Maximum DP Break Timer
(Maximum Break)
Use this option to de
fi
ne the maximum amount of time the loop must be opened to properly decode the dial
pulse digits sent from analog devices connected to single line PCBs.
Change this value only if the con-
nected analog devices are set to dial at a rate other than 10 PPS.
Features
• None
IntraMail Features
• None
Options
•
5-1275
mS
Default
•
100
mS