Message Notification
538
◆
IntraMail Features
DSX Software Manual
Unique Programming for Digital Pager Message Noti
fi
cation
1.
In
4202-08: Digital Pager Callback Number
(page 877), set the
Digital Pager Callback Number
portion
of the Message Noti
fi
cation callout number for a digital pager.
- This is the portion of the callout number that is appended to the pager service telephone number.
- By default, this option is
X*M#
, where:
X
is the number of the extension that generated the noti
fi
cation.
*
is a visual delimiter (to make the pager display easier to read).
M
is the number of new messages in the extension’s mailbox.
#
is the digit normally used by the pager service for positive disconnect.
2.
In
4202-09: Delay in Dialing Digital Pager Callback Number
(page 877)
,
set the delay (
0
-
99
seconds)
that occurs just before IntraMail dials the
4202-08: Digital Pager Callback Number
portion of the Mes-
sage Noti
fi
cation callout number for a digital pager.
- Set this delay so the pager service has enough time to connect to the digital pager before sending the
callback number. Your pager service may be able to help you determine the best value for this option.
- When placing a digital pager noti
fi
cation, the system:
- Seizes the line speci
fi
ed in
4112-01: Outgoing Dial 9 Group
.
- Dials the user-entered noti
fi
cation number (in
V-MAIL
+
OP
+
N
).
- Waits the
4202-09: Delay in Dialing Digital Pager Callback Number
interval.
- Dials the number entered in
4202-08: Digital Pager Callback Number
.
- The system assumes that the noti
fi
cation number will complete dialing approximately 4 seconds
after line seizure. This means that, by default, the Digital Pager Callback Number will be dialed
into the pager service about 13 seconds after line seizure.
1.
In
4202-02: Wait Between Digital Pager Callout Attempts
(page 873),
s
et the minimum time (
1
-
255
min-
utes) between unacknowledged or unanswered digital pager Message Noti
fi
cation callouts.
- A subscriber acknowledges a digital pager noti
fi
cation by logging onto their mailbox.
- After this interval expires, IntraMail will try the callout again (for up to the number of times set in
4202-06: Number of Callout Attempts
(page 876).
- If the system dials the callout number and the pager service is busy, it will retry the number in one
minute.
2.
In
4202-07: Send Pager Callout Until Acknowledged
(page 877)
,
enter
Yes
to have IntraMail continue to
retry a digital pager Message Noti
fi
cation callout until the noti
fi
cation is acknowledged.
- If this option is disabled (
No
), IntraMail will retry a digital pager Message Noti
fi
cation the number
of times speci
fi
ed in
4202-06: Number of Callout Attempts
(page 876).
- This option does not apply to Message Noti
fi
cation callouts to telephone numbers.
- A digital pager noti
fi
cation is considered acknowledged when the recipient logs onto the mailbox.
Other Related Features
Features
None
IntraMail Features
Security Code
(page 570)
To protect their mailbox from unauthorized access, the subscriber should be sure to record a Security
Code for your mailbox before enabling Message Noti
fi
cation.
1.
Set up the system-wide options that apply to the digital pager callback number.
2.
Set up the system-wide options that apply to digital pager callouts.