![NCR 74 OFX (7874) User Manual Download Page 95](http://html1.mh-extra.com/html/ncr/74-ofx-7874/74-ofx-7874_user-manual_3697090095.webp)
Chapter 4: Operation
4-3
The
Motion
Detector
is
located
at
the
upper
‐
right
of
the
Operator
Display
Panel.
The
laser
diodes
and
spinner
motor
turn
off
after
a
user
selectable
period
of
operator
inactivity.
This
prolongs
the
life
of
the
RealScan
74.
The
default
non
‐
active
time
is
fifteen
(15)
minutes,
but
can
be
increased
by
programming.
An
item
passing
in
front
of
the
Motion
Detector
causes
the
RealScan
74
to
turn
on.
This
movement
is
the
normal
item
scanning
movement.
Scan Adviser Status Indicator
25509
Scan Adviser Status Indicator
The
Scan
Adviser
Status
Indicator
is
located
diagonally
to
the
left
side
of
the
Operator
Display
Panel
buttons.
The
three
center
LEDs
turn
dim
green
when
the
RealScan
74
is
ready
to
read
a
bar
code.
When
the
scanner
reads
a
bar
code,
all
five
LEDs
light
up
brightly
for
an
instant.
During
power
‐
up,
if
the
unit
goes
into
the
Failure
Mode,
the
Scan
Adviser
Status
Indicator
displays
a
distinct
LED
pattern
of
colors
to
point
to
the
probable
scanner
error
code
that
is
used
by
the
field
engineer
to
repair
the
unit.
Voice
messages
are
used
to
indicate
errors
as
well.
The
Scan
Adviser
Status
Indicator
will
display
one
dimly
‐
lit
green
LED
in
the
center
when
the
RealScan
74
enters
sleep
mode.
When
using
IBM
‐
485
communications,
the
Scan
Adviser
Status
Indicator
slowly
flashes
a
red
‐
green
‐
green
pattern
nine
times,
then
delays,
then
repeats
indefinitely
when
the
RealScan
74
does
not
detect
the
12V
TRMPWR
voltage
from
the
IBM
terminal.
It
is
still
possible
to
successfully
scan
and
weigh
items
with
this
Scan
Adviser
pattern
displayed.
Possible
causes
for
this
red
‐
green
‐
green
indication
may
be
one
of
the
following:
•
Host
IBM
terminal
is
not
turned
on.
•
Interface
cable
is
not
connected
between
the
POS
and
scanner.
•
IBM
port
9x
being
used
by
the
scanner
is
not
generating
the
12V
TRMPWR
signal.
•
Rarely,
there
could
be
an
issue
with
the
scanner
digital
board
not
detecting
the
12V
coming
from
the
terminal.
Summary of Contents for 74 OFX (7874)
Page 1: ...NCR RealScan 74 OFX 7874 Release 1 1 User Guide 25315 B005 0000 1822 Issue C...
Page 16: ......
Page 42: ......
Page 240: ......
Page 246: ......
Page 248: ...A 2 Appendix A NCR Scanner Programming Tags Reset 11818 Default R0046 Programming Mode R0042...
Page 249: ...Appendix A NCR Scanner Programming Tags A 3 End R0043 Save and Reset R0044 Abort R0045...
Page 253: ...Appendix A NCR Scanner Programming Tags A 7 Hex 2 R0050 Hex 3 R0051 Hex 4 R0052...
Page 254: ...A 8 Appendix A NCR Scanner Programming Tags Hex 5 R0053 Hex 6 R0054 Hex 7 R0055...
Page 255: ...Appendix A NCR Scanner Programming Tags A 9 Hex 8 R0056 Hex 9 R0057 Hex A R0058...
Page 256: ...A 10 Appendix A NCR Scanner Programming Tags Hex B R0059 Hex C R0060 Hex D R0061...
Page 258: ......
Page 264: ......
Page 266: ......