![NCR 74 OFX (7874) User Manual Download Page 55](http://html1.mh-extra.com/html/ncr/74-ofx-7874/74-ofx-7874_user-manual_3697090055.webp)
Chapter 3: Installation 3-13
The
RealScan
74
maintains
an
audit
trail
of
scale
calibration
and
weighs
parameter
setting.
The
audit
trail
consists
of
two
even
counters.
Display
the
audit
trail
count
by
pressing
and
holding
the
Scale
Zero
button
on
the
Operator
Display
Panel.
The
display
alternates
between
Cal xxx
and
Par xxx
.
The
Cal
value
is
the
number
of
times
the
scale
has
been
calibrated.
The
Par
value
is
associated
with
the
weigh
parameter
setting
and
should
never
change.
Note:
The
audit
trail
displays
only
on
units
with
the
RealScan
25
Remote
Display.
Note:
Some
host
terminals
can
corrupt
the
calibration
settings
if
they
are
connected
during
scale
calibration.
Therefore,
NCR
recommends
disconnecting
the
interface
cable
before
starting
calibration
of
the
scale
and
then
reconnect
it
after
completing
the
calibration
procedure.
Perform the Calibration Procedure
Note:
If
a
protective
plastic
covering
is
present
on
the
Top
Plate
or
the
clear
plastic
door
below
the
Top
Plate,
ensure
that
it
is
removed
before
calibrating
the
Scale.
The
scale
firmware
controls
the
calibration
procedure.
It
waits
for
a
response
to
each
prompt
before
going
to
the
next
step.
The
firmware
uses
the
voice
feature
and
the
display
to
identify
how
much
weight
to
place
on
the
Top
Plate.
After
the
required
weight
has
been
placed
on
the
Top
Plate
and
the
Scale
Zero
button
is
pressed,
the
firmware
sounds
a
single
tone
and
goes
to
the
next
prompt.
The
calibration
procedure
can
be
ended
before
completion
by
turning
the
unit
off.
However,
if
this
is
done,
the
scale
must
still
be
calibrated
before
placing
it
into
service.
Note:
The
pound
and
kilogram
weights
used
for
calibration
are
not
equivalent
values.
They
are
the
actual
weights
the
firmware
needs
to
perform
the
calibration.
Note:
Turn
off
the
EAS
system
during
scale
calibration.
Summary of Contents for 74 OFX (7874)
Page 1: ...NCR RealScan 74 OFX 7874 Release 1 1 User Guide 25315 B005 0000 1822 Issue C...
Page 16: ......
Page 42: ......
Page 240: ......
Page 246: ......
Page 248: ...A 2 Appendix A NCR Scanner Programming Tags Reset 11818 Default R0046 Programming Mode R0042...
Page 249: ...Appendix A NCR Scanner Programming Tags A 3 End R0043 Save and Reset R0044 Abort R0045...
Page 253: ...Appendix A NCR Scanner Programming Tags A 7 Hex 2 R0050 Hex 3 R0051 Hex 4 R0052...
Page 254: ...A 8 Appendix A NCR Scanner Programming Tags Hex 5 R0053 Hex 6 R0054 Hex 7 R0055...
Page 255: ...Appendix A NCR Scanner Programming Tags A 9 Hex 8 R0056 Hex 9 R0057 Hex A R0058...
Page 256: ...A 10 Appendix A NCR Scanner Programming Tags Hex B R0059 Hex C R0060 Hex D R0061...
Page 258: ......
Page 264: ......
Page 266: ......