Chapter 5: Programming 5-95
Volume Levels
There
are
eight
standard
volume
settings
in
the
RealScan
74.
However,
there
is
a
programming
sequence
which
activates
eleven.
This
gives
the
operator
greater
flexibility
in
selecting
the
appropriate
volume
of
the
Good
read
Tone.
This
parameter
does
not
have
a
default
value,
however,
the
RealScan
74
is
shipped
from
the
factory
with
this
parameter
disabled.
The
default
setting
of
the
RealScan
74
is
eight
volume
levels.
•
Enable—
Program
Mode,
Hex
4,
Hex
2,
Hex
5,
and
Save
and
Reset
•
Disable—
Program
Mode,
Hex
4,
Hex
2,
Hex
4,
and
Save
and
Reset
Enable/Disable Volume Adjust Button
Through
programming,
the
Volume
Adjust
button
can
be
enabled
or
disabled.
If
disabled,
the
Good
Read
tone
volume
and
tone
are
set
using
the
various
programming
tags;
and
pressing
the
button
does
not
change
the
Good
Read
tone.
If
the
Volume
Adjust
Button
is
disabled,
be
sure
to
set
the
volume,
tone,
and
tone
length
to
the
desired
settings
first.
Note:
Scanning
the
Default
tag
enables
the
Volume
Adjust
Button.
•
Enable—
Program
Mode,
Hex
3,
Hex
E,
Hex
1,
and
Save
and
Reset
•
Disable—
Program
Mode,
Hex
3,
Hex
E,
Hex
0,
and
Save
and
Reset
Enable Volume Adjust Button
To
enable
the
Volume
Adjust
button,
scan
the
following
sequence
of
programming
tags.
These
tags
must
scanned
first
after
applying
power
to
the
RealScan
74.
1.
Program
Mode
—puts
scanner
in
the
programming
mode
2.
Hex
3
,
Hex
E
,
Hex
1
—enables
the
Volume
Adjust
button
3.
Save
and
Reset—
stores
the
enabled
setting,
and
then
resets
the
scanner
Disable Volume Adjust Button
To
disable
the
Volume
Adjust
Button,
scan
the
following
sequence
of
programming
tags.
These
tags
must
scanned
first
after
applying
power
to
the
RealScan
74.
This
sequence
sets
the
Good
Read
tone
frequency
(tone),
length,
and
volume.
1.
Program
Mode
—starts
the
scanner
in
the
programming
mode.
2.
Hex
1
,
Hex
1
—sends
programming
to
the
Good
Read
Tone
parameters
3.
Hex
A
,
Hex
1
—turns
on
the
Good
Read
tone
in
case
it
was
previously
turned
off
4.
Hex
B
—repeatedly
scan
this
tag
until
you
reach
the
desired
tone
frequency
(tone)
5.
Hex
C
—repeatedly
scan
this
tag
until
you
reach
the
desired
tone
length
6.
Hex
D
—repeatedly
scan
this
tag
until
you
reach
the
desired
tone
volume
Summary of Contents for 74 OFX (7874)
Page 1: ...NCR RealScan 74 OFX 7874 Release 1 1 User Guide 25315 B005 0000 1822 Issue C...
Page 16: ......
Page 42: ......
Page 240: ......
Page 246: ......
Page 248: ...A 2 Appendix A NCR Scanner Programming Tags Reset 11818 Default R0046 Programming Mode R0042...
Page 249: ...Appendix A NCR Scanner Programming Tags A 3 End R0043 Save and Reset R0044 Abort R0045...
Page 253: ...Appendix A NCR Scanner Programming Tags A 7 Hex 2 R0050 Hex 3 R0051 Hex 4 R0052...
Page 254: ...A 8 Appendix A NCR Scanner Programming Tags Hex 5 R0053 Hex 6 R0054 Hex 7 R0055...
Page 255: ...Appendix A NCR Scanner Programming Tags A 9 Hex 8 R0056 Hex 9 R0057 Hex A R0058...
Page 256: ...A 10 Appendix A NCR Scanner Programming Tags Hex B R0059 Hex C R0060 Hex D R0061...
Page 258: ......
Page 264: ......
Page 266: ......