VS300 Operations and Maintenance Manual
Operating the transmitter
Issue 8.0 2016-03-01
Page 2-79
Figure 2.54: IBOC Settings editing screens
•
IBOC Injection:
Use the up and down buttons to select an IBOC injection level between -20
and -10 dBc (in 0.1 dB increments), then press the accept (checkmark) button to save the
change. Press the cancel (
X
) button to discard changes and return to the previous menu.
•
PA Volts:
Use the up and down buttons to select a PA voltage between 6 and 53 V (in 1 V
increments), then press the accept (checkmark) button to save the change. Press the cancel
(
X
) button to discard changes and return to the previous menu.
•
Default LUT:
Use the up and down buttons to select
Flat LUT
or
LUT 1
through
LUT 12
, then
press the accept (checkmark) button to save the change. Press the cancel (
X
) button to dis-
card changes and return to the previous menu.