![Nautel VS300 Operation And Maintenance Manual Download Page 121](http://html2.mh-extra.com/html/nautel/vs300/vs300_operation-and-maintenance-manual_3601831121.webp)
VS300 Operations and Maintenance Manual
Operating the transmitter
Page 2-106
Issue 8.0 2016-03-01
•
Required Mask Delta
- Sets the value (between -10 db and 10 dB) that is considered to be
absolutely required. If this level is exceeded, the digital power from the transmitter will be
reduced if the PA voltage is at maximum. If the spectral mask still cannot be met and the set-
ting for it is enabled, the transmitter power set-point will be reduced.
•
Reduce Digital Power If Required: Select Yes or No. Selecting Yes enables a reduction in
injection level (digital power) if the spectrum mask requires it.
•
Reduce Power Set-Point If Required: Select Yes or No. Selecting Yes enables a reduction in
the transmitter power set-point if the sepctrum mask requires it.
HD Optimizing - Using the front panel UI
From the front panel UI, you can enable and configure various HD signal parameters (e.g., injection
level, TPO, etc.) in an attempt to optimize the digital signal’s overall efficiency. To view the
HD
Optimizer
screen, select
User Settings -> HD Optimizer
from the
Main Menu
Figure 2.88: HD Optimizer Menu
This menu has five sub-menu options:
–
Enable
–
Reduce Inj
–
Reduce TPO
–
Desired Delta
–
Required Delta
Use the up and down buttons to move the cursor to the desired setting and then press the right
button to enable editing of the setting.
shows the editing screens for the
HD Optimizer
menu. Within any of the editing screens, use the up and down buttons to edit a setting.
Press the accept (checkmark) button to save the change. Press cancel (
X
) to discard changes and
return to the previous menu.
Summary of Contents for VS300
Page 2: ......
Page 4: ......
Page 8: ...VS300 Operations and Maintenance Manual Page viii Issue 8 0 2016 03 01...
Page 14: ...VS300 Operations and Maintenance Manual Description Page 1 6 Issue 8 0 2016 03 01...
Page 228: ......