VS300 Operations and Maintenance Manual
Non-standard maintenance
Issue 8.0 2016-03-01
Page 4-1
Section 4:
Non-standard maintenance
This section provides instructions for performing non-standard maintenance on the VS300
transmitter. This section includes the following topics:
•
•
Configuring an audio loss backup preset - see page 4-5
Upgrading software
Periodically, enhancements or improvements to the operating system are identified and made
available. Perform a software upgrade, as required, as follows:
Parts and tools
•
Laptop (i.e., local computer for direct connection) or network computer with Windows and
Internet Explorer Web browser
•
CAT5 Ethernet cable
•
Upgrade software (
*.tgz
file), provided via email or web download
Preliminary checks
1. Determine the current software revision installed. Via the advanced user interface (AUI)
screen, go to
Menu
/
System Settings
/
Upgrade Software
. Note the software version in the
Current Version field i.e., 4.0.0.99.
2. Contact Nautel for the most recent software revision and download *.tgz file to a laptop or
network location.
Note:
Nautel recommends you perform a software upgrade at the transmitter site.
For port-forwarded transmitters, uploading of the .tgz file must occur locally or on the transmitter
side of the router.