Performing on-air checks
You should check the on-air quality of the transmitter’s signal periodically. This check can be done
locally at the transmitter site, or remotely from another location in the transmitter’s coverage area.
Interval
Every 12 months, or as required by law.
Parts and tools
•
High-quality receiver, compatible with the modulation scheme used on the transmitter.
Procedure
1. Monitor the transmitter signal to identify any problems:
– Use a high quality receiver to monitor audio quality.
– Take a portable receiver to different locations in your coverage areas to identify any
problems with the antenna pattern or areas of localized interference.
2. Obtain the
Proof of Performance
document that was completed during factory testing and
provided with the transmitter. Use the front panel UI or the remote AUI to compare current
transmitter meter readings with those in the
Proof of Performance
document.
Note:
Nautel completes the Proof of Performance document with the transmitter operating at 98 MHz,
terminated into a precision 50 ohm load. Measurements made at other operating frequencies may not
yield the same readings. Your front panel meter readings may not be exactly the same as shown, but
if an out-of-tolerance condition exists, an alarm will be displayed.