Remote Inputs - AUI
Using the
Remote Inputs
tab (see
), you can configure up to 10 remote
inputs that allow you to remotely control various operational characteristics of the transmitter. Unless
otherwise noted, these inputs are only accepted by the transmitter if the remote/local status is set to
remote.
Nautel sets remote input defaults prior to shipping. See the VS300 Pre-installation Manual for details.
Select the desired remote input (1 through 10) from the list. The
Channel
and
Control
settings for
the selected input, as well as the current logic level (1 or 0), are displayed on the right-hand side of the
page. You can define the
Channel
and
Control
settings as follows:
Select Input Channel - AUI
You can configure remote inputs 1 through 10 for one of a variety of control inputs. Click the existing
Channel
bar to display the
Select a Remote
window (see
). From this
window select one of the following options by clicking
OK
:
•
Not Assigned
. No effect on transmitter operation, regardless of logic level.
•
RF On/Off
. Same as pressing the
RF On
(telling the system to provide RF power, if possible)
or the
RF Off
button on the local AUI. There are 2
inputs configured by default; one for
Falling Edge, Turn On
and one for
Falling Edge, Turn Off
I.
•
Reset
. Causes a system reset. Same as pressing
Reset
button on the bottom banner.
•
Force Host Reset
. Allows the user to force a host (SBC) reset to the AUI, thus rebooting the
AUI via a hardware parallel remote input (controlled by a third party remote control unit).
•
Inc/Dec RF Power
. Activating these inputs will increment/decrement the preset power level
by a fixed amount (1% of rated power).
•
Preset: NAME
. Selects the associated preset (from a list of all pre-defined presets) as active.
If you save a change to a remote input via the remote AUI, it will also be displayed on the front panel
UI screen.