VS300 Operations and Maintenance Manual
Operating the transmitter
Page 2-166
Issue 8.0 2016-03-01
Figure 2.141: Select a Remote (input window)
Configure Input control logic - AUI
You can configure the active/inactive control logic for each of the 10 remote inputs. Click the
existing
Logic
bar to display the applicable drop-down menu options, which may include:
•
Rising Edge Turn On/Reset
. Logic ‘1’ (high or rising edge) activates the input (or causes a
reset, as appropriate).
•
Falling Edge Turn On/Reset
. Logic ‘0’ (low or trailing edge) activates the input (or causes a
reset, as appropriate).
•
Rising Edge Turn Off
. Logic ‘1’ (high or rising edge) de-activates the input.
•
Falling Edge Turn Off
. Logic ‘0’ (low or trailing edge) de-activates the input.
•
Falling Edge Toggle
. Logic ‘0’ (low or trailing edge) de-activates the input; next logic ‘0’ (low
or trailing edge) activates the input.
•
Rising Edge Toggle
. Logic ‘1’ (high or rising edge) activates the input; next logic ‘1’ (high or
rising edge) de-activates the input.
•
Rising Edge, Turn On. Falling Edge Turn Off
. Logic ‘1’ (high or rising edge) activates the
input; logic ‘0’ (low or trailing edge) de-activates the input.
•
Falling Edge, Turn On. Rising Edge Turn Off
. Logic ‘0’ (low or trailing edge) activates the
input; logic ‘1’ (high or rising edge) de-activates the input.
•
Active High, Increase
. Logic ‘1’ (high) causes a power increase.
•
Active Low, Increase
. Logic ‘0’ (low) causes a power increase.