VS1 Operations and Maintenance Manual
Routine maintenance
Issue 3.1 2013-10-01
Page 3-5
Table 3.1: Expected Transmitter Meter Readings
Meter Parameter
(displayed on front panel UI
or remote AUI
Meter Value at ...
88 MHz
98 MHz
108 MHz
Forward (forward power)
1250 W
1250 W
1250 W
Reflected (reflected power)
0.16 W
0.00 W
0.56 W
PA Volts A
40.3 V
41.3 V
42.9 V
Preamp Curr
111 mA
117 mA
101 mA
IPA Curr
3.75 A
3.84 A
3.81 A
PA1 Curr
11.4 A
10.2 A
9.60 A
PA2 Curr
9.75 A
10.8 A
11.1 A
PA3 Curr
9.77 A
11.1 A
11.3 A
PA4 Curr
11.3 A
10.1 A
9.79 A
PA Temp
32.5°C
33.1°C
36.0°C
Temp 2
33.2°C
33.7°C
36.0°C
+48V
47.9 V
47.9 V
47.7 V
+15V
14.9 V
14.9 V
14.9 V
-15V
-15.4 V
-15.4 V
-15.4 V
+5V
4.96 V
4.97 V
4.96 V
+3.3V
3.26 V
3.26 V
3.26 V
+1.8V
1.81 V
1.81 V
1.81 V
+1.2V
1.20 V
1.20 V
1.20 V
Battery
2.99 V
2.99 V
2.99 V
Fan 1
6350 RPM
6299 RPM
6325 RPM
Fan 2
6613 RPM
6624 RPM
6595 RPM
Fan 3
6210 RPM
6195 RPM
6215 RPM
TCXO
10.0 MHz
10.0 MHz
10.0 MHz
VSWR
1.02
1.00
1.05
Summary of Contents for VS1
Page 2: ......
Page 4: ......
Page 8: ...VS1 Operations and Maintenance Manual Page viii Issue 3 1 2013 10 01...
Page 12: ...VS1 Operations and Maintenance Manual Page xii Issue 3 1 2013 10 01...
Page 24: ...VS1 Operations and Maintenance Manual Description Page 1 6 Issue 3 1 2013 10 01...
Page 26: ...VS1 Operations and Maintenance Manual Issue 3 1 2013 10 01 Page 1 8...
Page 30: ......
Page 32: ......
Page 34: ......
Page 36: ......
Page 223: ......