VS1 Operations and Maintenance Manual
Operating the transmitter
Issue 3.1 2013-10-01
Page 2-91
Viewing Transmitter Status
You can view the VS1’s operational status using the AUI’s
Transmitter Status page - see Figure 2.80
.
This page shows current active alarms to aid in fault diagnosis. To view the
Transmitter Status page
,
click the
Status
button in the AUI’s bottom banner. Click
X
to return to the home page.
You can also use the transmitter front panel UI to view active alarms (see
Transmitter Log - Using the
front panel on page 2-28
).
Figure 2.80: Transmitter Status page
The
Transmitter Status
page displays all active transmitter alarms. Alarms are listed by their host
device (
Controller or Exciter
), alarm name and severity level [a single orange
!
indicates low severity
(RF output not affected); a single red
!
indicates medium severity (RF output is reduced); three red
!
indicates high severity (RF output is inhibited)]. Refer to the VS1 Troubleshooting Manual for
detailed information on alarm details such as root cause and troubleshooting tips.
Click the
Reset
button at the bottom of any AUI screen to attempt to clear any latching alarms that
are holding the transmitter in an “off-air” state (see
Reset: on page 2-18
). If the offending alarm has
cleared, the transmitter should resume operation.
Summary of Contents for VS1
Page 2: ......
Page 4: ......
Page 8: ...VS1 Operations and Maintenance Manual Page viii Issue 3 1 2013 10 01...
Page 12: ...VS1 Operations and Maintenance Manual Page xii Issue 3 1 2013 10 01...
Page 24: ...VS1 Operations and Maintenance Manual Description Page 1 6 Issue 3 1 2013 10 01...
Page 26: ...VS1 Operations and Maintenance Manual Issue 3 1 2013 10 01 Page 1 8...
Page 30: ......
Page 32: ......
Page 34: ......
Page 36: ......
Page 223: ......