VS1 Operations and Maintenance Manual
Operating the transmitter
Page 2-80
Issue 3.1 2013-10-01
•
Enable:
Select ON or OFF.
•
Data Source:
Select Internal, Ext. ASCII, Ext. UECP, ASCII Over IP, or UECP Over IP.
•
Baud Rate:
Select 150 bps, 300 bps, 600 bps, 1.2 kbps, 2.4 kbps, 4.8 kbps, 9.6 kbps,
19.2 kbps, 38.4 kbps, 57.6 kbps or 115.2 kbps.
•
RDS Level:
Select a value between 0 and 10%.
•
RDS Phase:
Select a value between 0 and 360 degrees.
•
PS Name:
Enter an 8-character name. Use the right and left arrows to move the cursor to the
desired character. Use the up and down arrows to edit the character.
•
PI Code:
Enter a hex value between 0x0000 and 0xFFFF.
•
Program Type:
Select the program type from various choices.
•
Traffic Flags:
Select None, TA/TP, TP or TA.
•
Music/Speech:
Select Music or Speech.
•
DI Code:
See
Figure 2.65 on page 2-81
.
•
AF Data:
See
Figure 2.66 on page 2-81
.
•
Local Echo:
Select ON or OFF.
Note:
For an ASCII Over IP data source, RDS information should be sent to the IP address of the
VS1, port 7005.
Note:
For title/artist functionality, the VS1 supports the radio text (RT) data type, using the UECP
or Ext. ASCII data source. PS scrolling is not currently supported.
Summary of Contents for VS1
Page 2: ......
Page 4: ......
Page 8: ...VS1 Operations and Maintenance Manual Page viii Issue 3 1 2013 10 01...
Page 12: ...VS1 Operations and Maintenance Manual Page xii Issue 3 1 2013 10 01...
Page 24: ...VS1 Operations and Maintenance Manual Description Page 1 6 Issue 3 1 2013 10 01...
Page 26: ...VS1 Operations and Maintenance Manual Issue 3 1 2013 10 01 Page 1 8...
Page 30: ......
Page 32: ......
Page 34: ......
Page 36: ......
Page 223: ......