VS1 Operations and Maintenance Manual
Operating the transmitter
Page 2-148
Issue 3.1 2013-10-01
Select output channel - AUI
You can configure digital outputs 1 through 16 to monitor a variety of alarm and status outputs. Click
the existing
Channel
bar to display the
Select a Remote
window. From this window, select one of the
channels, then click
Load
to accept:
•
Not Assigned
. No alarm or status parameter is monitored.
•
Local/Remote
. The active logic level indicates local only control. The inactive logic level
indicates remote enabled.
•
RF On/Off
. The active logic level indicates the transmitter’s RF power stage is on (enabled).
The inactive logic level indicates the transmitter’s RF power stage is off.
•
Preset Status
(1-4 default). The active preset’s output will be indicated by a logic low. The
remaining, non-active preset outputs will be open collector.
•
Various Alarms
. The active logic level indicates that the selected alarm is occurring. Any
transmitter alarm can be selected as a digital output. Refer to the
VS1 Troubleshooting Manual
for a description of each alarm.
Figure 2.132:
Configure output control logic - AUI
You can configure the active/inactive logic for each of the 16 digital outputs. Click the existing
Logic
bar to display the applicable drop-down menu options. Some digital output default examples:
if the selected channel is
RF On/Off
, the drop-down options are:
•
Output Low When RF On
. Logic ‘0’ (low) indicates the output is true (RF is on); Logic ‘1’
(high) indicates the output is false (RF is off).
Summary of Contents for VS1
Page 2: ......
Page 4: ......
Page 8: ...VS1 Operations and Maintenance Manual Page viii Issue 3 1 2013 10 01...
Page 12: ...VS1 Operations and Maintenance Manual Page xii Issue 3 1 2013 10 01...
Page 24: ...VS1 Operations and Maintenance Manual Description Page 1 6 Issue 3 1 2013 10 01...
Page 26: ...VS1 Operations and Maintenance Manual Issue 3 1 2013 10 01 Page 1 8...
Page 30: ......
Page 32: ......
Page 34: ......
Page 36: ......
Page 223: ......