Dual In-line Package (DIP) switches U28 and U29 select the base address. U29 selects address
lines A8 through A15, and U28 selects address lines A4 through A7. Press the side labeled
0
to
select a logical zero for the corresponding address bit. Press the side labeled
1
to select a logical
one. Figure 3-3 shows the configuration for the base address default setting 1000 hex.
1
2
3
456
O
F
F
O
N
This side down for logic 0
This side down for logic 1
U28
7
I1
I2
I3
A4
A5
A6
A7
0
Key
= the side you press down for Base Address 1000 hex
= not involved in Base Address selection
1
23
4
5
6
O
F
F
O
N
This side down for logic 0
This side down for logic 1
U29
7
A8
A9
A10
A11
A12
A13
A14
A15
0
1
8
Figure 3-3. Configuration for VMEbus Base Address 1000 hex (default setting)