Diagnostics and Troubleshooting
Section Seven
GPIB-1014P User Manual
7-2
© National Instruments Corporation
GPIB-1014P Hardware Installation Tests
1. Initialize TLC.
B
AUXMR = 2
Chip Reset
B
AUXMR = 0
Immediate execute pon
2. Send Chip Reset, then read registers and compare to reset values.
B
AUXMR = 2
Chip Reset
3
ISR1 = 0?
5
ISR2 = 0?
7
SPSR = 0?
9
ADSR = 40?
B
CPTR = 0?
3. Test ton, DO, ERR, CPTR, TA.
B
AUXMR = 2
Chip Reset
9
ADMR = 80
ton
B
AUXMR = 0
Immediate execute pon
9
ADSR = 42?
TA
3
ISR1 = 2?
DO
1
CDOR = 51
write data byte
B
CPTR = 51?
verify
3
ISR1 = 6?
DO + ERR
3
ISR1 = 0?
bits cleared when read
B
AUXMR = 2
Chip Reset
9
ADMR = 0
disable ton
B
AUXMR = 0
Immediate execute pon
9
ADSR = 40?
not TA
4. Check lon, LA.
B
AUXMR = 2
Chip Reset
3
IMR1 = 0
no interrupts
5
IMR2 = 0
no interrupts
9
ADMR = 40
lon
B
AUXMR = 0
Immediate execute pon
9
ADSR = 44?
LA
B
AUXMR = 2
Chip Reset
9
ADSR = 40?
not LA